Technical data
Control of MOBILE DCU S
Voltage supply
Ò
34
EDSMDAG EN 2.0
4.4
Control of MOBILE DCU S
The MOBILE device is controlled via the X1 terminal.
4.4.1
Voltage supply
Voltage supply
LV on−board supply system
12 V
24 V
Supply voltage TRM30
Rated voltage
V DC
12
24
Voltage range
V DC
8 ... 36
8 ... 36
Absolute voltage
(Pulse forms: ISO 16750−2)
(Behaviour: (ISO 16750−1)
Min.
V DC
6
6
Max.
V DC
60
60
Current consumption
A
0.4 ... 0.9
0.2 ... 0.6
Quiescent current at T
amb
= 25 °C
m
A
40 ... 60
40 ... 60
Switch on/off device TRM15
Switching threshold
V DC
8
8
Current consumption
mA
1.7
1.7
Secondary Wake Up (SWUP)
Switching threshold
V DC
8
8
Current consumption
mA
1.7
1.7
4.4.2
Digital inputs
Digital inputs
LV on−board supply system
12 V
24 V
Rated input voltage
V DC
12
24
Voltage range
V DC
8 ... 36
8 ... 36
Digital HIGH
V DC
7.8 ... 9
15.6 ... 18.2
Digital LOW
V DC
3 ... 4.5
6.2 ... 8.8
Hysteresis
V DC
3.3 ... 6
6.8 ... 12
Input resistance
k
W
4.75
Reference potential
TRM31
Diagnostics option
Wire breakage/short circuit
Use as analog inputs
Input frequency
Hz
0 ... 500
Resolution
Bit
4096