Technical data
Rated data of the devices for HV on−board supply system 800 V
DC/AC inverter
Ò
28
EDSMDAG EN 2.0
60 kW
30 kW
22 kW
15 kW
11 kW
7.5 kW
DC/AC inverter
Overcurrent cycle 60s
Operation for 60s with up to 150% of the continuous output current if afterwards a recovery time of 120s with
max. 50% of the continuous output current is observed.
Current consumption − HV
on−board supply system
A
14.7
20.2
27.6
39.5
58.8
106.6
Max. output power
kW
7.5
11
15
22
30
60
Max. output
current at
f
out
<5Hz
2 kHz,
permanent
A
12
16.5
22.5
32.3
48
87
4 kHz,
permanent
A
9.2
12.7
17.3
24.7
36.8
66.7
8 kHz,
permanent
A
5.6
7.7
10.5
15.1
22.4
40.6
16 kHz,
permanent
A
3.2
4.4
6
8.6
12.8
23.2
4 kHz auto
A
12
16.5
22.5
32.3
48
87
8 kHz auto
A
10.4
14.3
19.5
28
41.6
75.4
16 kHz auto
A
8
11
15
21.5
32
58
Max. output
current at
f
out
>5Hz
2 kHz,
permanent
A
16
22
30
43
64
116
4 kHz,
permanent
A
12
16.5
22.5
32.3
48
87
8 kHz,
permanent
A
8.8
12.1
16.5
23.7
35.2
63.8
16 kHz,
permanent
A
5.2
7.2
9.8
14
20.8
37.7
4 kHz auto
A
14.8
20.4
27.8
39.8
59.2
107.3
8 kHz auto
A
12
16.5
22.5
32.3
48
87
16 kHz auto
A
8
11
15
21.5
32
58
Max. output current for "socket" application (VAC)
f
out
<10Hz, VAC
16 kHz,
permanent
A
3.4
4.6
6.3
9.0
12.8
22
f
out
>10Hz, VAC
16 kHz,
permanent
A
6.1
8.4
11.4
16.3
22.7
41.2