Maintenance
Repair
Fuse change
58
BA_CSx8xx EN 4.0
8.3.3
Fuse change
Stop!
Damage of the device by non−permissible fuse possible
The baseboard in the device is protected by a fuse which will be damaged if
the supply voltage applied is too high.
Possible consequences:
ƒ
The device can be damaged if a non−approved fuse is installed.
Protective measures:
ƒ
The fuse may only be replaced by an approved type.
Approved types:
ƒ
Littelfuse 0454 004
CA
N
2
CA
N
2
CA
N1
MC-
POWER
F
AN2
F
AN3
C
F-
CARD
RESE
T
USB
-
μCON
BL
I
G
HT
ACCU
CR2
4
50
1
2
19
20
F
1
T4
A
0
ELx7xx−018
How to proceed:
1. Remove the MC Card, if inserted.
2. Remove the old fuse
from the support.
3. Insert a new approved fuse
into the support.