Define required input variables
Necessary input variables
Note
Symbol
Unit
Operating time / day
OD
Ambient temperature
T
V
°C
Site altitude amsl
H
m
Radial force
F
rad
N
Axial force
F
ax
N
Transmission element at the output
Gear wheels, sprockets …
Effective diameter of the transmission element
d
W
mm
Load torque
For short-term load peaks
M
L,max
Nm
In rated operation
M
L
Nm
In mains operation, M
L,max
/M
L
should be < 2.0 to
guarantee a safe start of the motor
Load speed
n
L,max
rpm
In inverter operation
n
L,min
rpm
Runtime for M
L,max
In inverter operation
%
External moments of inertia
J
ext
kgcm
2
Switching operations per hour
S
H
1/h
Determine correction factor
Operating modes S1, S2, S3, S6, and operating time
Operating mode S1
Operating mode S2
Operating mode S3
Operating mode S6
ED
k
L
ED
k
L
ED
k
L
ED
k
L
%
min
%
%
100
1.0
10
1.4 - 1.5
15
1.4 - 1.5
15
1.5 - 1.6
30
1.15 - 1.2
25
1.3 - 1.4
25
1.4 - 1.5
60
1.07 - 1.1
40
1.15 - 1.2
40
1.3 - 1.4
90
1.0 - 1.05
60
1.05 - 1.1
60
1.15 - 1.2
Installation height amsl
≤ 1000 m
≤ 2000 m
≤ 3000 m
≤ 4000 m
Correction factor
k
H
k
H
k
H
k
H
1
0.95
.90
.85
Ambient temperature
≤ 40 °C
≤ 45 °C
≤ 50 °C
Correction factor
k
TU
k
TU
k
TU
1
0.95
0.90
Mounting position
Gearboxes
Mounting position
M1
M2
M3
M4
M5
M6
Correction factor
k
E
k
E
k
E
k
E
k
E
k
E
g500-H
1.00
0.70
0.80
0.80
1.00
1.00
g500-S
1.00
0.70
0.80
0.85
0.80
0.90
g500-B
1.00
0.70
0.80
0.80
0.80
0.80