Extended Safety
Extended safety is part of the product version i950AExxxF1A.
DANGER!
Loss of the safety function.
A loss of the safety function causes an unsafe condition of the machine. The machine condition cannot be
controlled via the safety function.
▶
Always install the cables S1 and S2 in a protective manner according to EN ISO 13849-2, category 4.
The LEDs display the safety system status.
LED "RDY" (yellow)
State
Meaning
off
-
No status message active
on
-
Restart acknowledgement requested
Blinking 2 Hz
SOS active
Blinking 1 Hz
Service status
Parameter set transfer requested.
"ERR" LED (red)
State
Meaning
off
-
The device operates properly.
on
Critical device error
The device is defective and must be replaced.
Blinking 2 Hz
Safety bus error
No communication has been established via the
safety bus:
•
There is no valid configuration
•
The acceleration has not yet been completed
Blinking 1 Hz
Error in the safety system
One of the following errors has been recognized:
•
Monitoring device has been activated
•
Discrepancy of the input
•
Errors to be acknowledged
"ERR" LED (red)
State
Meaning
blinking with 1 Hz
-
Parameter set detected. Press the enable switch
to accept the parameter set.
LED
State
Meaning
LED "RDY"
Parameter set transfer in "Init" state
Safety address changed.
LED "ERR"
"Init"
Safety address changed.
Electrical installation
Functional safety
Extended Safety
137
Summary of Contents for i950-Cabinet
Page 2: ......
Page 4: ...4...
Page 29: ...22 kW Die Abmessungen in mm gelten f r 22 kW I95AE322F Mechanische Installation Abmessungen 29...
Page 49: ...I95AE322F 3 3 Elektrische Installation Anschluss an das IT Netz 49...
Page 51: ...I95AE390F I95AE411F 3 3 Elektrische Installation Anschluss an das IT Netz 51...
Page 103: ...22 kW The dimensions in mm apply to 22 kW I95AE322F Mechanical installation Dimensions 103...
Page 104: ...30 hp The dimensions in inch apply to 30 hp I95AE322F Mechanical installation Dimensions 104...
Page 123: ...I95AE322F 3 3 Electrical installation Connection to the IT system 123...
Page 125: ...I95AE390F I95AE411F 3 3 Electrical installation Connection to the IT system 125...
Page 153: ......