Parameter setting
Parameter setting using the keypad
8
L
EDK82EVXXX EN 2.0
2.1.2
Display elements and function keys
z
y
w x
v
t
u
s
88888
8888
888
8
a
b
c
d
e
j g f k i h
PS
m n o
p
q r
Hi
Hz
%sh
rpm
°C
Ω
m
A
V
Lo
8
0
3
1
2
4
6
5
7
E82ZBC002
Status displays
Meaning
Explanation
-
Ready for operation
,
Pulse inhibt active
Power outputs inhibited
+
Adjusted current limitation is exceeded in motor-mode or
generator-mode
C0022 (motor mode) or C0023 (generator mode)
.
Warning active
*
Active fault
Function bar 1
Meaning
Explanation
3
Setpoint selection via
AB
Not possible when password protection is active (display =
”loc”
)
0
Display function:
•
User menu, memory location 1 (C0517/1), display
•
Display active parameter set
Active after every mains connection
/
Code selection
Four-digit display of the active code number
4
Select subcodes
Three-digit display of the active subcode number
2
Change the parameter value of a (sub) code
Five-digit display of the current value
1
Display of values longer than 5 digits
1
H:
high-order positions
Display
”HI”
L:
low-order positions
Display
”lo”
Function bar 2
Meaning
Explanation
5
Select parameter set 1 ... 4 for changing
•
Display, e.g. PS
2
(
)
•
The parameter sets can only be activated via digital signals
(configuration with C0410)
6
Select system bus (CAN) devices
The selected device can be parameterised by the current drive
:
= function active
7
Select menu
user
List of codes in the user menu (C0517)
7
The user menu is active after mains switching
all
List of all codes
funci
Only specific codes for bus function modules, e.g.
INTERBUS, PROFIBUS-DP, LECOM-B, ...
Bargraph display
Value set under C0004 in %
(Lenze setting: Controller load C0056)
Display range: - 180 % ... + 180 % (every bar = 20 %)
Display of parameter set
In the mode
0
:
Display of the parameter set activated via digital signal
Otherwise:
Display of the parameter set active for changing
Select the single parameter sets in the mode
5
in the function
bar 2