Control connections
Control connections with M12 connectors
Via the digital inputs of the two M12 control connections, it is possible to switch between
different speeds and directions of rotation. Up to 5 different speed settings (e.g. creep speed
and normal speed in both directions, as well as stop) can thus be selected. In addition, the
operating state is indicated via a digital output.
Control connection X1 with M12 connector, A-coded, pins
Pin assignment
Con-
tact
Name
Meaning
1
n.c.
1
2
4
3
2
DI2
Digital input 2
3
GND-I
Earth of digital inputs
4
DI1
Digital input 1
Control connection X2 with M12 connector, A-coded, pins
Pin assignment
Con-
tact
Name
Meaning
1
24 V
24 V-supply (DO1 supply)
1
2
4
3
2
DI3
Digital input 3 (reference X1;3 = GND-I)
3
GND-O
Earth of digital outputs
4
DO1
Digital output 1
Mounting/ installation
Electrical installation
Control connections
64