I/O data transfer (implicit messages)
I/O configuration with »RSLogix 5000« version 20 or higher
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Settings for an "AC Drive Profile" application:
•
Select
"AC Drive"
connection.
In the example, the AC Drive Profile "Exclusive Owner - AC Drive Ext. Speed & Torque" is
used.
•
Set
Data type = INT
.
The INT data type is exchanged via ports MCI_IN and MCI_OUT of the Inverter Drive
8400 motec. The SINT data type requires an additional PLC logic for the conversion.
•
Set
Tag Suffix = 1
.
A tag suffix formulates a module-describing tag name.
9. Complete the settings with