Parameter data transfer
CTT2: Write code number
48
Lenze · Decentralised frequency inverter 8400 motec (AS-Interface option) · EDS84DMOTASI EN 5.0 - 02/2019
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
9.4
CTT2: Write code number
• Acyclic write request from master to slave:
• Response from slave to master is OK:
• Response from slave to master has failed:
Byte
Contents / value
0
CTT2: Code
• Index
0x13
(19): Acyclic write request
1
CTT2: Index
• Index
0x11
(17): Write code number
2
CTT2: Number of bytes
•
0x4
(4)
3
Index high
byte
Index = 0x5FFF (inverter code)
4
Index low
byte
5
Subindex
6
Reserved
Byte
Contents / value
0
CTT2: Code
• Index
0x53
(83): Acyclic write request is OK.
• Code number was written.
Byte
Contents / value
0
CTT2: Code
• Index
0x93
(147): Acyclic write request is not OK.
1
CTT2: Standard error code
2
Error code (MSB)
3
Error code
4
Error code
5
Error code (LSB)