Lenze · Decentralised frequency inverter 8400 motec (AS-Interface option) · EDS84DMOTASI EN 5.0 - 02/2019
47
Parameter data transfer
CTT2: Read code number
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
9.3
CTT2: Read code number
• Acyclic read request from the master to the slave:
• Response from slave to master is OK:
• Response from slave to master has failed:
Byte
Contents / value
0
CTT2: Code
• Index
0x12
(18): Acyclic read request
1
CTT2: Index
• Index
0x12
(18): Read code number
2
CTT2: Number of bytes
• Value depends on the master.
Byte
Contents / value
0
CTT2: Code
• Index
0x52
(82): Acyclic read request is OK.
3
Index high
byte
Index = 0x5FFF (inverter code)
4
Index low
byte
5
Subindex
6
Reserved
Byte
Contents / value
0
CTT2: Code
• Index
0x92
(146): Acyclic read request is not OK.
1
CTT2: Standard error code
2
Error code (MSB)
3
Error code
4
Error code
5
Error code (LSB)