Technical data
Communication time
l
16
EDS82ZAFPC201 EN 4.0
Terminal
X3.2/
Designation
Function / level
+
PES
Additional HF shield termination
A
T/R(A)
RS485 data line A
B
T/R(B)
RS485 data cable B
CN
CNTR
For function see PROFIBUS standard *)
l
Level during data transmission: CNTR = HIGH
(+5 V DC, reference:GND3)
VP
For function see PROFIBUS standard *)
l
U = +5 V DC (reference:GND3)
l
I
max
= 10 mA
40
GND3
Reference potential for PROFIBUS network *)
7
GND1
Reference potential for X3.1/20 and X3.2/20
39
GND2
Reference potential of the
l
digital inputs at X3.1/E1 and X3.1/E2
l
controller inhibit (CINH) at X3.2/28
28
CINH
Controller inhibit
l
Start = HIGH (+12 ... +30 V DC)
l
Stop = LOW (0 ... +3 V DC)
(reference: GND2)
20
DC voltage source for internal supply of controller inhibit (CINH)
l
+20 V DC (reference: GND1)
l
I
max
= 20 mA
59
External DC voltage supply for the function module
l
+24VDC
±
10% (reference: GND1)
l
Current consumption on 24 V DC: 80 mA
The current for looping through the supply voltage to other nodes via
terminal 59 must be max. 3A.
*) E.g. for repeater connection
4.5
Communication time
The communication time is the time between the start of a request and the arrival of the
corresponding response.
The communication times depend on ...
ƒ
the processing time in the controller
ƒ
the transmission delay time
– the baud rate
– the telegram length
Processing time 8200vector / 8200motec / starttec
There are no interdependencies between parameter data and process data.
ƒ
Parameter data: approx. 30 ms + 20 ms tolerance
ƒ
Process data: approx. 3 ms + 2 ms tolerance