Technical data
General data and operating conditions
3
47
LDCDS-CPC9100 DE/EN 1.0
3
Technical data
3.1
General data and operating conditions
Conformity and approval
Conformity
CE
EN 61000 6-2 (4)
EMC Directive for industrial premises
EN 55022, EN 55024 Equipment of information technology
Protection of persons and equipment
Enclosure
Housing
IP20
Front and housing
cover
IP54
Class of protection
1
Mounting conditions
Mounting place
19” control cabinet according to DIN 41494
Mounting position
horizontal
Ambient conditions
Climatic
Storage
without UPS
-10 ... +60 °C
with UPS
-10 ... +40 °C
Transport
without UPS
-10 ... +60 °C
with UPS
-10 ... +40 °C
Operation
dependent on the equipment (
47)
Relative humidity
10 ... 90 %, non-condensing
Site altitude
< 3000 m amsl
Note!
The failure probability of an electronic component increases with the ambient
temperature to which the component is subjected. Regarding the
serviceability and reliability, particular attention should be paid to the cooling
of the device. For every application, you should take care to keep the heating
of the device as low as possible.
Permissible ambient temperatures
Basic device with
without UPS
with
UPS
≤
40 W additional load by PCI
extensions
≤
100 W additional load by PCI
extensions
[°C]
[°C]
Mobile Intel
®
Celeron D 3.2 GHz
5 ... 45
5 ... 40
5 ... 35
Intel
®
Core
™
2 Duo 1.8 GHz
Intel
®
Core
™
2 Duo 2.13 GHz