31
Which values you have to enter in the CVs in order to map
functions to function outputs is shown in the table below:
Function output
CV
H
G
F
E
D
C
B
A
33
F0 forward
128
64
32
16
8
34
F0 backward
128
64
32
16
8
35
Function 1
128
64
32
16
8
36
Function 2
128
64
32
16
8
37
Function 3
128
64
32
16
8
38
Function 4
128
64
32
16
8
4
2
1
39
Function 5
128
64
32
16
8
4
2
1
40
Function 6
128
64
32
16
8
4
2
1
41
Function 7
128
64
32
16
8
4
2
1
42
Function 8
128
64
32
16
8
4
2
1
43
Function 9
16
8
4
2
1
44
Function 10
16
8
4
2
1
45
Function 11
16
8
4
2
1
46
Function 12
16
8
4
2
1
Table 14-1
To map a function of the digital system to a function output, look
for the section where
- the row of the desired function
intersects with
- the column of the desired function output.
Enter the number found in the respective CV.
For the purpose of clarification, the table above shows the
default settings in bold print.
Example 1:
Let us return to the above example: "The value 64 in CV36
determines that function output D will react to function 2".
Col
um
n:
func
tion out
put
CV
H
G
F
E
D
C
B
A
33
F0 forward
128
64
32
16
8
34
F0 backward
128
64
32
16
8
35
Function 1
128
64
32
16
8
Row: function
36
Function 2
128
64
32
16
8