background image

2

Locomotive decoder LE104XF

DIGITAL plus

What can LW120 do:

Use as a turnout throwing module:

A pair of keys or a single key in connection with a group key
directly throws a turnout, sets a signal, activates an uncoupler or
other device.

What can LW120 do in the future:

Use as train path module:

Pressing a single key calls up a switching chain on the tower cab.
This option is of special interest for setting multi-display signals.

Use as start-goal module:

Two keys are pressed after each other; the first key is the “start”
key, the second is the “goal” key. This key combination then calls
up the associated switching chain in the tower cab. In this setup,
any key can be both start and goal key. The logic always
evaluates the key pressed first as the “start” one and the following
key as the “goal” one.

Installation

LW120 has 4 holes for installation using the included screws. Use
the plastic tubes as spacers. Make sure that you do not damage or
bend any components when attaching the module. If you use
screws different from the ones included, please ensure that the
maximum diameter of 3mm (1/8”) is not exceeded. Similarly, the
screw heads must not touch traces or components on the circuit
board.

Summary of Contents for Digital Plus LW120

Page 1: ...GITAL plus LW120 Input Board LW120 is the interface between tower cab LW100 and the keys on your display control panel It only works in connection with tower cab LW100 Information LW120 Version 1 0 Ar...

Page 2: ...the first key is the start key the second is the goal key This key combination then calls up the associated switching chain in the tower cab In this setup any key can be both start and goal key The l...

Page 3: ...rnout from to 0 0 0 0 1 16 1 0 0 0 17 32 0 1 0 0 33 48 1 1 0 0 49 64 0 0 1 0 65 80 1 0 1 0 81 96 0 1 1 0 97 112 1 1 1 0 113 128 0 0 0 1 129 144 1 0 0 1 145 160 0 1 0 1 161 176 1 1 0 1 177 192 0 0 1 1...

Page 4: ...different possibilities here differing in operation and the number of keys needed Version 1 You use one pair of keys for each magnetic device You press one key for diverge stop the other for straight...

Page 5: ...need to connect several wires Please note that you must not connect the PLUS and MINUS terminals of one key module with the same terminals of another key module Version 2 You first choose Diverge Stop...

Page 6: ...p key and in addition key T S1 then the terminal of output 1 of the LS100 110 that is programmed for turnout addresses 33 to 36 is activated The terminals labeled PLUS and MINUS are designed as double...

Page 7: ...elements from these manufacturers S E S Schmidt in Berlin ROCO GBS Standard HEKI here only elements 9023D and 9024D Registration section Fill in and return to Lenz Agency of North America PO Box 143 C...

Page 8: ...hone 978 250 1494 Fax 978 455 LENZ support lenz com www lenz com This equipment complies with Part 15 of FCC Rules Operation is subject to the following two conditions 1 this device may not cause harm...

Reviews: