Locomotive decoder LE104XF

DIGITAL plus

Example:

The key module is programmed for turnout addresses 33 to 48.

If you now press the “PLUS” group key and in addition key T/S1,
then the “+” terminal of output 1 of the LS100/110 that is
programmed for turnout addresses 33 to 36 is activated.

If you press the “MINUS” group key and in addition key T/S1, then
the “-” terminal of output 1 of the LS100/110 that is programmed
for turnout addresses 33 to 36 is activated.

The terminals labeled “PLUS” and “MINUS” are designed as
double terminals, in case you need to connect several wires.

Please note that you must not connect the “PLUS” and “MINUS”
terminals of one key module with the same terminals of another
key module! If you need several key modules in your graphic
display control panel, then you will need separate group keys for
each module!

Summary of Contents for Digital Plus LW120

Page 1: ...GITAL plus LW120 Input Board LW120 is the interface between tower cab LW100 and the keys on your display control panel It only works in connection with tower cab LW100 Information LW120 Version 1 0 Ar...

Page 2: ...the first key is the start key the second is the goal key This key combination then calls up the associated switching chain in the tower cab In this setup any key can be both start and goal key The l...

Page 3: ...rnout from to 0 0 0 0 1 16 1 0 0 0 17 32 0 1 0 0 33 48 1 1 0 0 49 64 0 0 1 0 65 80 1 0 1 0 81 96 0 1 1 0 97 112 1 1 1 0 113 128 0 0 0 1 129 144 1 0 0 1 145 160 0 1 0 1 161 176 1 1 0 1 177 192 0 0 1 1...

Page 4: ...different possibilities here differing in operation and the number of keys needed Version 1 You use one pair of keys for each magnetic device You press one key for diverge stop the other for straight...

Page 5: ...need to connect several wires Please note that you must not connect the PLUS and MINUS terminals of one key module with the same terminals of another key module Version 2 You first choose Diverge Stop...

Page 6: ...p key and in addition key T S1 then the terminal of output 1 of the LS100 110 that is programmed for turnout addresses 33 to 36 is activated The terminals labeled PLUS and MINUS are designed as double...

Page 7: ...elements from these manufacturers S E S Schmidt in Berlin ROCO GBS Standard HEKI here only elements 9023D and 9024D Registration section Fill in and return to Lenz Agency of North America PO Box 143 C...

Page 8: ...hone 978 250 1494 Fax 978 455 LENZ support lenz com www lenz com This equipment complies with Part 15 of FCC Rules Operation is subject to the following two conditions 1 this device may not cause harm...

Reviews: