Figure 44. M.2 drive slots
Table 217. M.2 drive slots
1
Slot 0
2
Slot 1
Step 3. Secure the M.2 drives in the backplane.
Figure 45. Securing the M.2 drives
Attention:
Make sure the two nubs on the retainer are in the small holes on the M.2 backplane
when the retainer is slid forward.
Slide the retainer forward (toward the connector) until you hear a soft “click” sound.
After installing an M.2 drive option:
1. Install the M.2 backplane. See “Install the M.2 backplane” on page 244.
2. If you have no additional options to install in the I/O tray, install it. See “Install the I/O tray” on page 335.
Note:
You will need to configure the M.2 drive to complete the installation. See the information that comes
with the M.2 drive option for information.
Install a riser
Risers are in the I/O tray that is accessed from the rear of the server.
Install adapters before installing the risers.
Install the riser for slot 1 to 4 (riser 1)
The riser for adapter slot 1 to 4 (riser 1) is in the I/O tray that is accessed from the rear of the server. After
installing adapters in the riser, insert the riser in the I/O tray and secure it with two captive screws.
S002
237