Diagnostic Error Code
FRU/Action
170-199-XXX
Voltage Sensor(s) test failed, cause
unknown
1. See “Undetermined problems” on page 71
2. Flash the system and re-test. See “Updating
(flashing) the BIOS from a disc” on page 391
3. Replace component under function test
170-250-XXX 170-251-XXX
Voltage Sensor(s) Voltage
limit error
1. Power supply
2. System board
170-254-XXX
Voltage Sensor(s) Voltage Regulator
Module error
1. Voltage Regulator Module (VRM)
2. Microprocessor
3. System board
175-000-XXX
Thermal Sensor(s) Test Passed
No action
175-0XX-XXX
Thermal Sensor(s) failure
1. Flash system
2. System board
175-195-XXX
Thermal Sensor(s) Test aborted by user
Information only Re-start the test, if necessary
175-196-XXX
Thermal Sensor(s) test halt, error threshold
exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
175-197-XXX
Thermal Sensor(s) test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using the
Setup Utility program” on page 43
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
175-198-XXX
Thermal Sensor(s) test aborted
1. If a component is called out, make sure it is
connected and/or enabled
2. Flash the system and re-test. See “Updating
(flashing) the BIOS from a disc” on page 391
3. Go to “Undetermined problems” on page 71
175-199-XXX
Thermal Sensor(s) test failed, cause
unknown
1. See “Undetermined problems” on page 71
2. Flash the system and re-test. See “Updating
(flashing) the BIOS from a disc” on page 391
3. Replace component under function test
175-250-XXX 175-251-XXX
Thermal Sensor(s) limit error
1. Check fans
2. Check Power supply voltages
3. Microprocessor
4. System board
185-000-XXX
Asset Security Test Passed
No action
185-XXX-XXX
Asset Security failure
1. Flash system
2. System board
185-278-XXX
Asset Security Chassis Intrusion
1. Assure Asset Security Enabled
2. C2 Cover Switch
3. System board
201-000-XXX
System Memory Test Passed
No action
Chapter 7
.
Symptom-to-FRU index
65
Summary of Contents for ThinkCentre M71e
Page 6: ...iv ThinkCentre Hardware Maintenance Manual ...
Page 8: ...2 ThinkCentre Hardware Maintenance Manual ...
Page 15: ...Chapter 2 Safety information 9 ...
Page 16: ... 18 kg 37 lb 32 kg 70 5 lb 55 kg 121 2 lb 10 ThinkCentre Hardware Maintenance Manual ...
Page 20: ...14 ThinkCentre Hardware Maintenance Manual ...
Page 21: ...1 2 Chapter 2 Safety information 15 ...
Page 22: ...1 2 16 ThinkCentre Hardware Maintenance Manual ...
Page 28: ...22 ThinkCentre Hardware Maintenance Manual ...
Page 29: ...1 2 Chapter 2 Safety information 23 ...
Page 33: ...Chapter 2 Safety information 27 ...
Page 34: ...1 2 28 ThinkCentre Hardware Maintenance Manual ...
Page 38: ...32 ThinkCentre Hardware Maintenance Manual ...
Page 54: ...48 ThinkCentre Hardware Maintenance Manual ...
Page 78: ...72 ThinkCentre Hardware Maintenance Manual ...
Page 112: ...106 ThinkCentre Hardware Maintenance Manual ...
Page 400: ...394 ThinkCentre Hardware Maintenance Manual ...
Page 405: ......
Page 406: ...Part Number 0B02865 Printed in USA 1P P N 0B02865 0B02865 ...