The
server
might
have
the
following
RAS
features
(the
features
vary
depending
on
your
model):
v
Advanced
Configuration
and
Power
Interface
(ACPI)
v
Advanced
Desktop
Management
Interface
(DMI)
features
v
Automatic
error
retry
or
recovery
v
Automatic
memory
downsizing
on
error
detection
v
Automatic
restart
on
nonmaskable
interrupt
(NMI)
v
Automatic
Server
Restart
(ASR)
logic
supporting
a
system
restart
when
the
operating
system
becomes
unresponsive
v
Automatic
server
restart
after
a
power
failure,
based
on
the
BIOS
setting
v
Availability
of
microcode
level
v
Boot-block
recovery
v
Built-in,
menu-driven
setup,
system
configuration,
and
redundant
array
of
independent
disks
(RAID)
configuration
v
Built-in
monitoring
for
fan,
power,
temperature,
and
voltage
v
CD-based
diagnostic
programs
v
Cooling
fans
with
speed-sensing
capability
v
Customer
support
center
that
is
available
24
hours
a
day,
7
days
a
week
2
v
Error
codes
and
messages
v
Error
correcting
code
(ECC)
double-data-rate
2
(DDR2)
synchronous
dynamic
random-access
memory
(SDRAM)
with
serial
presence
detect
(SPD)
v
Error
logging
of
POST
failures
v
Hot-swap
Serial
Attached
SCSI
(SAS)
and
hot-swap
Serial
ATA
(SATA)
hard
disk
drives
v
Integrated
Ethernet
controller
v
Support
for
an
optional
IBM
Remote
Supervisor
Adapter
II
SlimLine
v
Key-lock
support
for
physical
security
v
Memory
change
messages
posted
to
the
error
log
v
Baseboard
management
controller
(BMC)
or
service
processor
v
Power
management
v
Power-on
self-test
(POST)
v
Read-only
memory
(ROM)
checksums
v
Redundant
Ethernet
capabilities
(requires
an
optional
Ethernet
adapter)
with
failover
support
v
Simple-swap
Serial
Advanced
Technology
Attachment
(SATA)
hard
disk
drives
v
Standby
voltage
for
system-management
features
and
monitoring
v
System
auto-configuring
from
the
configuration
menu
v
System-error
LED
on
the
front
bezel
and
diagnostic
LEDs
on
the
system
board
v
Upgradeable
baseboard
management
controller
(BMC)
firmware
v
Upgradeable
microcode
for
POST,
basic
input/output
system
(BIOS)
code,
and
read-only
memory
(ROM)
resident
code,
locally
or
over
a
LAN
v
Vital
product
data
(VPD);
includes
serial-number
information
and
replacement
part
numbers,
stored
in
nonvolatile
memory,
for
easier
remote
maintenance
2. Service
availability
will
vary
by
country.
Response
time
varies;
may
exclude
holidays.
Chapter
1.
The
ThinkServer
TD100
and
TD100x
server
7
Summary of Contents for TD100 - THINKSERVER 2.0G 2GB DVD 670W 6X7 TFF
Page 1: ...ThinkServer TD100 and TD100x Types 4203 4204 4205 4206 6398 6399 6419 and 6429 User Guide ...
Page 2: ......
Page 3: ...ThinkServer TD100 and TD100x Types 4203 4204 4205 4206 6398 6399 6419 and 6429 User Guide ...
Page 92: ...78 ThinkServer TD100 and TD100x Types 4203 4204 4205 4206 6398 6399 6419 and 6429 User Guide ...
Page 97: ......
Page 98: ...Part Number 46U0858 Printed in USA 1P P N 46U0858 ...