Select
this
choice
to
exit
from
the
Configuration/Setup
Utility
program.
If
you
have
not
saved
the
changes
that
you
have
made
in
the
settings,
you
are
asked
whether
you
want
to
save
the
changes
or
exit
without
saving
them.
Using
passwords
You
can
use
any
combination
of
up
to
seven
characters
(A
-
Z,
a
-
z,
and
0
-
9)
for
the
power-on
(user)
password
or
the
administrator
password.
If
you
set
both
a
power-on
password
and
an
administrator
password,
you
can
type
either
password
at
the
password
prompt
that
is
displayed
as
you
start
the
server.
However,
if
you
want
to
change
the
settings
in
the
Configuration/Setup
Utility
program,
you
must
type
the
administrator
password
to
access
the
full
Configuration/Setup
Utility
menu.
If
you
type
the
power-on
password,
you
have
access
to
only
the
limited
Configuration/Setup
Utility
menu.
Keep
a
record
of
the
passwords
in
a
secure
place.
If
you
forget
the
power-on
password
or
administrator
password,
you
can
regain
access
to
the
server
through
one
of
the
following
methods:
v
If
you
have
forgotten
the
power-on
password
and
an
administrator
password
is
set,
type
the
administrator
password
at
the
power-on
password
prompt.
Start
the
Configuration/Setup
Utility
program
and
change
the
power-on
password.
v
Remove
the
battery
and
then
install
the
battery.
Using
the
Boot
Menu
program
The
Boot
Menu
program
is
a
built
in,
menu-driven
configuration
program
that
you
can
use
to
temporarily
redefine
the
first
startup
device
without
changing
settings
in
the
Configuration/Setup
Utility
program.
To
use
the
Boot
Menu
program,
complete
the
following
steps:
1.
Restart
the
server.
2.
Press
F12.
3.
Select
the
startup
device.
The
next
time
the
server
is
started,
it
returns
to
the
startup
sequence
that
is
set
in
the
Configuration/Setup
Utility
program.
Configuring
the
Broadcom
NetXtreme
Gigabit
Ethernet
controller
The
Ethernet
controller
is
integrated
on
the
system
board.
It
provides
an
interface
for
connecting
to
a
10
Mbps,
100
Mbps,
or
1
Gbps
network
and
provides
full
duplex
(FDX)
capability,
which
enables
simultaneous
transmission
and
reception
of
data
on
the
network.
If
the
Ethernet
port
in
the
server
supports
auto-negotiation,
the
controller
detects
the
data-transfer
rate
(10BASE-T,
100BASE-TX,
or
1000BASE-T)
and
duplex
mode
(full-duplex
or
half-duplex)
of
the
network
and
automatically
operates
at
that
rate
and
mode.
You
do
not
have
to
set
any
jumpers
or
configure
the
controller.
However,
you
must
install
a
device
driver
to
enable
the
operating
system
to
address
the
controller.
For
device
drivers
and
information
about
configuring
the
Ethernet
controller,
see
the
Broadcom
NetXtreme
Gigabit
Ethernet
Software
CD
that
comes
with
the
server.
To
find
updated
information
about
configuring
the
controller,
complete
the
following
steps.
66
ThinkServer
TD100
and
TD100x
Types
4203,
4204,
4205,
4206,
6398,
6399,
6419,
and
6429:
User
Guide
Summary of Contents for TD100 - THINKSERVER 2.0G 2GB DVD 670W 6X7 TFF
Page 1: ...ThinkServer TD100 and TD100x Types 4203 4204 4205 4206 6398 6399 6419 and 6429 User Guide ...
Page 2: ......
Page 3: ...ThinkServer TD100 and TD100x Types 4203 4204 4205 4206 6398 6399 6419 and 6429 User Guide ...
Page 92: ...78 ThinkServer TD100 and TD100x Types 4203 4204 4205 4206 6398 6399 6419 and 6429 User Guide ...
Page 97: ......
Page 98: ...Part Number 46U0858 Printed in USA 1P P N 46U0858 ...