Severity
Error
User Response
Complete the following steps:
1. You must AC-cycle the system to re-enable affected DIMM connector or re-enable manually
using F1 setup
2. If the node has been recently installed, serviced, moved, or upgraded, check to ensure that
DIMMs are firmly seated and that no foreign material can be seen in the DIMM connector. If
either condition is observed, correct and retry with the same DIMM. (Note: Event Log may
contain a recent 00580A4 event denoting detected change in DIMM population that could
be related to this problem.)
3. If problem persists, replace the DIMM identified by LightPath and/or event log entry.
4. If problem re-occurs on the same DIMM connector, swap the other DIMMs on the same memory
channel across channels one at a time to a different memory channel or Processor. (check
service information for this product/Install guide for population requirements for sparing/paring
modes). If problem follows a moved DIMM to a different memory channel, replace that DIMM.
5. Check IBM support site for an applicable service bulletin or firmware update that applies to this
memory error.
6. (Trained service technician only) If problem stays with the original DIMM connector, re-inspect
DIMM connector for foreign material and remove, if found. If connector is damaged, replace
system board.
7. (Trained service technician only) Remove affected Processor and inspect Processor socket pins
for damaged or mis-aligned pins. If damage is found, or this is an upgrade Processor, replace
system board. If there are multiple Processor’s, swap Processor’s to move affected Procesor to
another Processor socket and retry. If problem follows the affected Processor (or there is only
one Processor), replace the affected Processor.
8. (Trained Service technician only) Replace the system board.
•
S.68005 [S.68005] An error has been detected by the the IIO core logic on Bus %. The Global Fatal
Error Status register contains %. The Global Non-Fatal Error Status register contains %. Please
check error logs for the presence of additional downstream device error data.
Explanation:
Critical IOH-PCI Error
Severity
Error
User Response
Complete the following steps:
1. Check log for a separate error for an associated PCIe device and service that error.
2. Check IBM support site for an applicable service bulletin or firmware update for the system or
adapter that applies to this error.
3. (Trained Service technician only) Replace the system board.
•
W.11004 [W.11004] A processor within the system has failed the BIST.
Explanation:
Processor Self Test Failure Detected
Severity
418
Lenovo System x3250 M4 Installation and Service Guide
Summary of Contents for System x3250 M4
Page 1: ...Lenovo System x3250 M4 Installation and Service Guide Machine Type 2583 ...
Page 6: ...iv Lenovo System x3250 M4 Installation and Service Guide ...
Page 74: ...60 Lenovo System x3250 M4 Installation and Service Guide ...
Page 98: ...84 Lenovo System x3250 M4 Installation and Service Guide ...
Page 136: ...122 Lenovo System x3250 M4 Installation and Service Guide ...
Page 144: ...130 Lenovo System x3250 M4 Installation and Service Guide ...
Page 418: ...404 Lenovo System x3250 M4 Installation and Service Guide ...
Page 596: ...582 Lenovo System x3250 M4 Installation and Service Guide ...
Page 604: ...Taiwan BSMI RoHS declaration 590 Lenovo System x3250 M4 Installation and Service Guide ...
Page 612: ...598 Lenovo System x3250 M4 Installation and Service Guide ...
Page 613: ......
Page 614: ......