© Copyright 2015 Lenovo
Chapter 2: Switch Components
27
Using redundant power can minimize the power disruption during a power supply
failure and extend the expected lifetime of each power supply by operating normally
in a conservative power mode.
For proper airflow when operating the switch with only one power supply module,
the empty power supply bay must be protected by a blank cover module.
There is no power switch on the G8052 power modules; the switch powers up when
power is supplied through the power cord to one or both power supplies.
Power LEDs
On the front of the switch, the Power LED on the management panel indicates the
general status of the power supplies. The LED flashes when only one power cord is
connected, and is steady when both power cords are connected (see
“System
Status LEDs” on page 22
).
Additional LED indicators are located on the rear panel of the switch, on the
individual power supply modules. The following table describes the power supply
module LED behavior.
Table 8. Power supply module status LED behavior
LED
State
Functional Meaning
Service ( ! )
Amber
Power supply failure.
Off
Power supply is operational.
OK
Green
DC output power is present.
Off
DC output power is OK.
AC
Green
AC power is OK.
Off
No power. Output is disabled, or input
power is outside operating range.
Summary of Contents for RackSwitch G8052
Page 1: ...Lenovo RackSwitch G8052 Installation Guide ...
Page 10: ...10 RackSwitch G8052 Installation Guide ...
Page 14: ...14 RackSwitch G8052 Installation Guide ...
Page 18: ...18 RackSwitch G8052 Installation Guide ...
Page 28: ...28 RackSwitch G8052 Installation Guide ...
Page 52: ...52 RackSwitch G8052 Installation Guide ...