![Lenovo 70AR User Manual And Hardware Maintenance Manual Download Page 160](http://html.mh-extra.com/html/lenovo/70ar/70ar_user-manual-and-hardware-maintenance-manual_202586160.webp)
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
2. If the server is installed in a rack cabinet, remove the server from the rack cabinet and place it on a flat,
clean, and static-protective surface. See the
Rack Installation Instructions
that comes with the server.
3. Remove the server cover. See “Removing the server cover” on page 71.
4. Locate the front panel board. See “Front view of the server” on page 15.
5. Disconnect the front panel cable and the front panel USB cable from the front panel board.
6. Remove the two screws that secure the front panel board and then carefully remove the front panel
board from the chassis.
ID
Mem
CPU
PSU
Figure 114. Removing the front panel board
7. Touch the static-protective package that contains the new front panel board to any unpainted surface
on the outside of the server. Then, take the new front panel board out of the package.
Note:
Carefully handle the front panel board by its edges.
146
ThinkServer RD540 User Guide and Hardware Maintenance Manual
Summary of Contents for 70AR
Page 14: ...xii ThinkServer RD540 User Guide and Hardware Maintenance Manual ...
Page 20: ...6 ThinkServer RD540 User Guide and Hardware Maintenance Manual ...
Page 64: ...50 ThinkServer RD540 User Guide and Hardware Maintenance Manual ...
Page 186: ...172 ThinkServer RD540 User Guide and Hardware Maintenance Manual ...
Page 199: ......
Page 200: ......