2. If the server is installed in a rack cabinet, remove the server from the rack cabinet and place it on a flat,
clean, and static-protective surface. See the
Rack Installation Instructions
that comes with the server.
3. Remove the server cover. See “Removing the server cover” on page 71.
4. Disconnect the cable from the ThinkServer RAID Super Capacitor Module and then remove the two
screws that secure the ThinkServer RAID Super Capacitor Module bracket. Then, hold the bracket with
the ThinkServer RAID Super Capacitor Module and lift it up from the chassis.
ID
Mem
CPU
PSU
Figure 102. Removing the ThinkServer RAID Super Capacitor Module with the bracket from the chassis
5. Gently press the tab
1
on the bracket and remove the ThinkServer RAID Super Capacitor Module from
the bracket at the same time.
Figure 103. Removing the ThinkServer RAID Super Capacitor Module from the bracket
6. Touch the static-protective package that contains the new ThinkServer RAID Super Capacitor Module
to any unpainted surface on the outside of the server. Then, take the new ThinkServer RAID Super
Capacitor Module out of the package.
Chapter 6
.
Installing, removing, or replacing hardware
135
Summary of Contents for 70AR
Page 14: ...xii ThinkServer RD540 User Guide and Hardware Maintenance Manual ...
Page 20: ...6 ThinkServer RD540 User Guide and Hardware Maintenance Manual ...
Page 64: ...50 ThinkServer RD540 User Guide and Hardware Maintenance Manual ...
Page 186: ...172 ThinkServer RD540 User Guide and Hardware Maintenance Manual ...
Page 199: ......
Page 200: ......