![Lenovo 70AR User Manual And Hardware Maintenance Manual Download Page 111](http://html.mh-extra.com/html/lenovo/70ar/70ar_user-manual-and-hardware-maintenance-manual_202586111.webp)
Notes:
• If you remove the TR 700 Battery, you will lose the backup power for the ThinkServer RAID 700 Adapter.
• Use any documentation that comes with the TR 700 Battery and follow those instructions in addition to
the instructions in this topic.
To remove the TR 700 Battery, do the following:
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
2. If the server is installed in a rack cabinet, remove the server from the rack cabinet and place it on a flat,
clean, and static-protective surface. See the
Rack Installation Instructions
that comes with the server.
3. Remove the server cover. See “Removing the server cover” on page 71.
4. Remove the cooling shroud. See “Removing and reinstalling the cooling shroud” on page 75.
5. Locate the ThinkServer RAID 700 Adapter, which is installed in the PCI Express card slot on the riser
card assembly 2. Then, disconnect all cables from the ThinkServer RAID 700 Adapter.
6. Remove the riser card assembly 2. The procedure is similar to that of the riser card assembly 1. See
“Replacing the riser card assembly 1” on page 147.
7. Remove the ThinkServer RAID 700 Adapter from the riser card assembly 2. See “Replacing the RAID
card” on page 87.
8. Remove the three screws first. Then, hold the TR 700 Battery and lift it up from the ThinkServer RAID
700 Adapter.
Note:
Center the screwdriver when you remove the screws to avoid possible damage to any parts.
Figure 58. Removing the TR 700 Battery
9. Reinstall the ThinkServer RAID 700 Adapter to the riser card assembly 2. See “Replacing the RAID
card” on page 87.
10. Reconnect cables to the ThinkServer RAID 700 Adapter. See “Mini-SAS to mini-SAS signal cable
connections” on page 38.
11. Reinstall the riser card assembly 2. The procedure is similar to that of the riser card assembly 1. See
“Replacing the riser card assembly 1” on page 147.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
Chapter 6
.
Installing, removing, or replacing hardware
97
Summary of Contents for 70AR
Page 14: ...xii ThinkServer RD540 User Guide and Hardware Maintenance Manual ...
Page 20: ...6 ThinkServer RD540 User Guide and Hardware Maintenance Manual ...
Page 64: ...50 ThinkServer RD540 User Guide and Hardware Maintenance Manual ...
Page 186: ...172 ThinkServer RD540 User Guide and Hardware Maintenance Manual ...
Page 199: ......
Page 200: ......