Bauer
7 Maintenance
GEL 235/235x/203x
27
7 Maintenance
The encoder contains no parts that require maintenance.
Do
not
try to repair the encoder yourself. Necessary repairs may only be made by
BAUER or an explicitly-authorized agent.
No change may be made to devices that are operated in areas
subject to
explosion
. Service work may only be performed by specially-trained and authorized
personnel.
When?
What?
Encoder faulty
Change the encoder.
Regularly
Check the encoder for damage.
Ex design: Damage to the device that can compromise the ex-
plosion protection is not permitted – the device must be taken out
of service and it must be ensured that it can no longer be oper-
ated.
Check all seals for possible damage and to ensure their tight fit.
Check all screws, couplings, and clamping elements as well as
cable entries to ensure a tight fit.
Ex design: Check that the guidelines according to EN 60079-19,
EN 60079-17, and EN 61241-17 are adhered to.
(1)
Clean the encoder (see further below).
If necessary
(not Ex)
Change the plug (not component of the scope of supply). Con-
sider that when so doing, you must shorten the length of the con-
nection cable.
Cleaning the encoder
To avoid damage to the encoder, please heed the following points:
– Do not use a high-pressure cleaner.
– If the plug connector has been unplugged, do not allow water, dirt or other sub-
stances to penetrate its open parts.
Clean the encoder with water or a non-corrosive cleanser.
(1)
According to these guidelines, the company operating electrical systems in areas subject to explosion is obligated
to have these checked by an electrician to ensure their proper condition.