6 Technical specification
6.1 Mechanical data
dimensions (W × H × D)
fastening
control panel thickness
electrical connection
lead cross section
screws
weight
display
colour
digits
digit height
indicator LEDs
data storage
data conservation
read cycles
write cycles
96 × 48 × 108 mm (acc. to DIN 43 700)
in the panel cut-out 92 × 45 mm with clamping
frame, screws M3
max. 11 mm
2 plug-in-type connecting terminals, 10 and 8
poles, 5 mm grid
1…1,5 mm
2
with end splices
M2.6
DC version: approx. 200 g
AC version: approx. 420 g
7-segment-LED with leading zero elimination
and programmable decimal point
red
6
14 mm
4
non-volatile memory
> 10 years
unlimited
> 100 000
6.2 Electrical data
Voltage supply
a) DC U
b
overload protection
12…24 V= -5% / +10%
external fuse:
12 V= : 0.25 A fast-blow / 0.25 A slow-blow
(IEC 127 / UL 198)
24 V= : 0.16 A slow-blow / 0.20 A slow-blow
(IEC 127 / UL 198)