3
P
ROGRAMMING
7
Setting range: 0.0005 … 99.9999 (standard setting: 1.0000)
If you enter a value less than 0.0005 the error message
Error0
will be
emitted. To enter a new value press the store key.
3.2.2 Decimal point
Use the cursor key to select one of the 4 possible variants:
–
.
= display without decimal point
–
.
– = display with one decimal
–
.
–
– = display with two decimals
–
.
–
–
– = display with three decimals
3.3 System parameters
To enter this operating plane press the store key
and the cursor key
simultaneously upon switching on the supply voltage. The following parameters
and their variants are available (standard settings are printed in boldface):
Parameter
Variant
Description
1. Count inputs A, B
In
dIF
A, B as differential inputs: A accumulative, B subtractive
Input A
+
Input B
-
1
0
-1
1
0
1
0
Count
E110401A
ud
A is the count input, B is the counting direction input
(up/down)
1
0
-1
1
0
1
0
Count
Input A
count pulses
Input B
up/down
E110401B