TP − 3 to 5 Ton R−22 Heat Pump Outdoor Units
ARI RATINGS
1
ARI Standard 210/240 Ratings
Capacity − Btuh
Efficiency
Total Watts
COP
I d
U it M d l N
Expansion
Cooling
High
Temp
Low
Temp
HSPF
Cool
High Low High Low
Indoor Unit Model No.
Expansion
Device
Cooling Temp.
Heating
Temp.
Heating SEER EER
IV
V
Cool
High
Heat
Low
Heat
High
Heat
Low
Heat
TPA060S2
5 TON
Air Handlers
Air Handlers
54,000 55,500
35,600 13.00 11.00 7.70 6.70 4910 4595 4130 3.54 2.52
4
CB27UH−060 (Up−Flow / Horizontal)
Factory TXV
56,000 55,000
35,400 13.00 11.00 7.70 6.70 5090 4660 4145 3.46 2.50
4
CB31MV−51 (Multi−Position)
Factory TXV
57,000 55,000
35,800 13.00 11.00 7.70 6.70 5180 4765 4240 3.42 2.48
3
CB30U−65 (Up−Flow)
Factory TXV
57,000 55,500
35,800 13.00 11.00 7.70 6.70 5180 4795 4265 3.40 2.46
5
CB26UH−060−R (Up−Flow / Horizontal)
2
56J20
57,000 55,500
35,800 13.00 11.00 7.70 6.70 5180 4730 4230 3.44 2.48
3
CB30M−65 (Multi−Position)
Factory TXV
57,500 55,000
35,400 13.00 11.50 7.70 6.70 5000 4655 4155 3.46 2.50
4
CB31MV−65 (Multi−Position)
Factory TXV
Up−Flow Indoor Coils + Furnaces
Up−Flow Coils + Furnaces
55,000 55,000
35,600 13.00 11.50 7.70 6.70 4785 4940 4365 3.26 2.38 C33−60D
4
G61MPV−60D−135
2
56J20
55,500 55,000
35,600 13.00 11.50 7.70 6.70 4825 4855 4290 3.32 2.42 C33−60D
4
G60UHV−60D−135
2
56J20
56,000 55,500
36,000 13.00 11.00 7.70 6.70 5090 4995 4455 3.26 2.36 C33−62C
4
G61MPV−60C−090
2
56J20
56,000 55,000
35,600 13.00 11.50 7.70 6.70 4870 4920 4335 3.28 2.40 C33−62D
4
G61MPV−60D−135
2
56J20
56,500 55,500
35,800 13.00 11.50 7.70 6.70 4915 4950 4400 3.28 2.38 C33−62C
4
G60UHV−60C−110
2
56J20
56,500 55,000
35,600 13.50 11.50 7.70 6.70 4915 4835 4275 3.34 2.44 C33−62D
4
G60UHV−60D−135
2
56J20
56,500 55,500
36,000 13.00 11.00 7.70 6.70 5135 4975 4445 3.26 2.38 C33−62C
4
G61MPV−60C−110
2
56J20
57,000 55,500
35,800 13.00 11.50 7.70 6.70 4955 4895 4390 3.32 2.38 C33−62C
4
G60UHV−60C−090
2
56J20
Down−Flow Indoor Coils + Furnaces
Down−Flow Coils + Furnaces
53,500 55,000
35,400 13.00 11.00 7.70 6.70 4865 4695 4155 3.44 2.50 CR33−50/60C−F
4
G60DFV−60C−090
2
56J20
54,000 55,000
35,600 13.00 11.00 7.70 6.70 4910 4670 4145 3.46 2.52 CR33−60D−F
4
G60DFV−60D−135
2
56J20
Horizontal Indoor Coils + Furnaces
Horizontal Coils + Furnaces
55,000 55,000
35,600 13.00 11.50 7.70 6.70 4785 4990 4365 3.24 2.38 CH33−60D−2F
4
G61MPV−60D−135
2
56J20
55,000 55,000
35,600 13.00 11.50 7.70 6.70 4785 4935 4370 3.26 2.38 CH33−62D−2F
4
G61MPV−60D−135
2
56J20
55,500 55,000
35,600 13.00 11.50 7.70 6.70 4825 4895 4305 3.30 2.42 CH33−60D−2F
4
G60UHV−60D−135
2
56J20
55,500 55,500
35,600 13.00 11.50 7.70 6.70 4825 4540 4100 3.58 2.54 CH23−68
4
G61MPV−60D−135
2
56J20
56,000 54,500
35,400 13.50 11.50 7.70 6.70 4870 4895 4300 3.26 2.42 CH33−62D−2F
4
G60UHV−60D−135
2
56J20
56,500 55,500
35,600 13.50 11.50 7.70 6.70 4915 4470 4040 3.64 2.58 CH23−68
4
G60UHV−60D−135
2
56J20
57,500 55,000
35,600 13.00 11.00 7.70 6.70 5225 5000 4415 3.26 2.38 CH33−50/60C−2F
4
G60UHV−60C−090
2
56J20
57,500 55,000
35,800 13.00 11.00 7.70 6.70 5225 5015 4395 3.22 2.38 CH33−50/60C−2F
4
G60UHV−60C−110
2
56J20
NOTE − These are the only approved system match−ups. For other matches, contact the Lennox Applications Department.
NOTE − Ratings for C33 coils include all cased and uncased coils.
NOTE − When used with gas furnaces, a dual−fuel control (i.e. FM21) or a control system with dual−fuel capabilities (i.e. Harmony III, LZP−2 or LZP−4) must be used (ordered extra).
1
Certified in accordance with USE certification program which is based on ARI Standard 210/240 with 25 ft. (7.6 m) of connecting refrigerant lines;
Cooling Ratings −
95
_
F (35
_
C) outdoor air temperature and 80
_
F (27
_
C) db/67
_
F (19
_
C) wb entering indoor coil air.
High Temperature Heating Ratings −
47
_
F (8
_
C) db/43
_
F (6
_
C) wb outdoor air temperature and 70
_
F (21
_
C) db entering indoor coil air.
Low Temperature Heating Ratings −
17
_
F (−8.3
_
C) db/15
_
F (−9.4
_
C) wb outdoor air temperature and 70
_
F (21
_
C) db entering indoor coil air.
2
Factory installed expansion valve or RFC on indoor unit MUST be replaced with valve specified (if equipped).
3
Blower must be capable of time−off blower delay. Indoor Blower Off Delay Relay (
58M81
) is recommend for field installation.
4
Blower control must be set for a time−off blower delay.
5
Most popular air handler combination.