TP − 3 to 5 Ton R−22 Heat Pump Outdoor Units
ARI RATINGS
1
ARI Standard 210/240 Ratings
Capacity − Btuh
Efficiency
Total Watts
COP
I d
U it M d l N
Expansion
Cooling
High
Temp
Low
Temp
HSPF
Cool
High Low High Low
Indoor Unit Model No.
Expansion
Device
Cooling Temp.
Heating
Temp.
Heating SEER EER
IV
V
Cool
High
Heat
Low
Heat
High
Heat
Low
Heat
TPA036S2
3 TON
Air Handlers
Air Handlers
34,400 33,600 20,800 13.00 11.00 7.70 6.75 3150 2825 2695 3.48 2.26
3
CB30M−41 (Multi−Position)
Factory TXV
34,400 33,600 20,800 13.00 11.00 7.70 6.70 3155 2830 2710 3.48 2.24
3
CB30U−41/46 (Up−Flow)
Factory TXV
34,400 34,000 21,200 12.20 10.40 7.70 6.70 3245 2925 2755 3.40 2.26
3,6
CB29M−46 (Multi−Position)
Factory TXV
34,600 33,600 20,800 13.00 11.00 7.70 6.80 3130 2790 2670 3.52 2.28
3
CB30M−46 (Multi−Position)
Factory TXV
34,600 34,200 21,600 12.00 10.30 7.50 6.60 3350 3045 2840 3.24 2.22
3
CB29M−51 (Multi−Position)
Factory TXV
34,800 33,400 20,800 13.00 11.00 7.70 6.80 3125 2765 2650 3.54 2.30
4
CB31MV−41 (Multi−Position)
Factory TXV
34,800 33,200 20,600 13.50 11.00 7.70 6.70 3165 2705 2570 3.60 2.34
4
CB27UH−036 (Up−Flow / Horizontal)
Factory TXV
35,200 33,800 21,000 13.00 11.00 7.70 7.10 3165 2760 2515 3.58 2.44
5
CB26UH−036 (Up−Flow/Horiz.)
Factory TXV
36,400 33,000 20,400 14.00 12.00 7.70 6.70 3035 2700 2505 3.58 2.38
4
CB27UH−042 (Up−Flow / Horizontal)
2
56J19
Up−Flow Indoor Coils + Furnaces
Up−Flow Coils + Furnaces
34,200 33,200 20,600 13.00 11.00 7.70 6.80 3080 2875 2610 3.38 2.32 C33−36B
4
G60UHV−36B−090
2
56J19
34,200 33,200 20,600 13.00 11.00 7.70 6.75 3065 2885 2615 3.38 2.30 C33−36C
4
G61MPV−36C−090
2
56J19
34,200 33,200 20,600 13.00 11.00 7.70 6.80 3080 2875 2610 3.38 2.32 C33−42B
4
G60UHV−36B−090
2
56J19
34,400 33,200 20,800 13.00 11.00 7.70 6.80 3100 2865 2615 3.40 2.32 C33−36C
4
G61MPV−60C−090
2
56J19
34,600 33,200 20,600 13.00 11.00 7.70 6.85 3085 2840 2590 3.42 2.32 C33−36C
4
G60UHV−60C−110
2
56J19
34,600 33,200 20,800 13.00 11.00 7.70 6.80 3095 2850 2605 3.42 2.34 C33−36C
4
G61MPV−60C−110
2
56J19
Down−Flow Indoor Coils + Furnaces
Down−Flow Coils + Furnaces
34,600 33,400 20,800 13.00 11.00 8.20 7.20 3060 2675 2425 3.66 2.52 CR33−30/36B−F
4
G60DFV−36B−090
2
56J19
34,600 33,400 20,800 13.00 11.00 8.20 7.20 3075 2695 2435 3.64 2.50 CR33−30/36C−F
4
G61MPV−36C−090
2
56J19
34,600 33,200 20,600 13.00 11.00 7.70 7.05 3060 2760 2495 3.52 2.42 CR33−48B−F
4
G60DFV−36B−090
2
56J19
34,800 33,600 20,800 13.00 11.00 8.20 7.20 3105 2680 2440 3.68 2.50 CR33−30/36C−F
4
G61MPV−60C−090
2
56J19
35,000 33,600 20,800 13.00 11.00 8.20 7.25 3100 2665 2430 3.70 2.50 CR33−30/36C−F
4
G61MPV−60C−110
2
56J19
Horizontal Indoor Coils + Furnaces
Horizontal Coils + Furnaces
34,000 33,200 20,800 13.00 11.00 7.70 7.00 3075 2785 2510 3.50 2.42 CH23−41
4
G60UHV−36B−090
2
56J19
34,000 33,200 20,800 13.00 11.00 7.70 7.00 3065 2795 2510 3.48 2.42 CH23−41
4
G61MPV−36C−090
2
56J19
34,400 33,400 20,800 13.00 11.00 7.70 7.05 3090 2765 2505 3.54 2.44 CH23−41
4
G61MPV−60C−110
2
56J19
34,600 33,200 20,600 13.00 11.00 7.70 6.80 3075 2835 2625 3.44 2.30 CH33−36C−2F
4
G61MPV−36C−090
2
56J19
34,800 33,400 20,800 13.00 11.00 7.70 6.80 3100 2810 2625 3.48 2.32 CH33−36C−2F
4
G61MPV−60C−090
2
56J19
35,000 33,400 20,800 13.00 11.00 7.70 6.85 3100 2800 2615 3.50 2.32 CH33−36C−2F
4
G61MPV−60C−110
2
56J19
NOTE − These are the only approved system match−ups. For other matches, contact the Lennox Applications Department.
NOTE − Ratings for C33 coils include all cased and uncased coils.
NOTE − When used with gas furnaces, a dual−fuel control (i.e. FM21) or a control system with dual−fuel capabilities (i.e. Harmony III, LZP−2 or LZP−4) must be used (ordered extra).
1
Certified in accordance with USE certification program which is based on ARI Standard 210/240 with 25 ft. (7.6 m) of connecting refrigerant lines;
Cooling Ratings −
95
_
F (35
_
C) outdoor air temperature and 80
_
F (27
_
C) db/67
_
F (19
_
C) wb entering indoor coil air.
High Temperature Heating Ratings −
47
_
F (8
_
C) db/43
_
F (6
_
C) wb outdoor air temperature and 70
_
F (21
_
C) db entering indoor coil air.
Low Temperature Heating Ratings −
17
_
F (−8.3
_
C) db/15
_
F (−9.4
_
C) wb outdoor air temperature and 70
_
F (21
_
C) db entering indoor coil air.
2
Factory installed expansion valve or RFC on indoor unit MUST be replaced with valve specified (if equipped).
3
Blower must be capable of time−off blower delay. Indoor Blower Off Delay Relay (
58M81
) is recommend for field installation.
4
Blower control must be set for a time−off blower delay.
5
Most popular air handler combination.