background image

E N G I N E E R I N G  D A T A

TP

T−CLASS

t

 SPLIT SYSTEM UNITS

R−22 − 60 HZ

H E A T  P U M P  O U T D O O R  U N I T S

Bulletin No. 210438

November 2007

Supersedes October 2007

SEER up to 13.0

3 to 5 Tons

Cooling Capacity − 34,000 to 57,500 Btuh

Heating Capacity − 33,600 to 55,500 Btuh

MODEL NUMBER IDENTIFICATION 

T P A

Y

1

036 S

4

2 n

Major Design Sequence

A = 1st Generation

B = 2nd Generation

Brand/Family

T = T−Class

t

 Product Line

Unit Type

P = Heat Pump Outdoor Unit

Nominal Cooling Capacity − Tons

036 = 3 Tons
048 = 4 Tons
060 = 5 Tons

Cooling Efficiency

S = Standard Efficiency

Minor Design Sequence

1 = 1st Revision
2 = 2nd Revision
3 = 3rd Revision

Voltage

Y = 208/230V-3 phase-60hz
G = 460V-3 phase-60hz

Refrigerant Type

2 = R−22

Part Load Capability

N = No part load, single stage compressor

Coil type

4 = Four−sided

Summary of Contents for TPA036S2

Page 1: ...NTIFICATION T P A Y 1 036 S 4 2 n Major Design Sequence A 1st Generation B 2nd Generation Brand Family T T Classt Product Line Unit Type P Heat Pump Outdoor Unit Nominal Cooling Capacity Tons 036 3 To...

Page 2: ...f Designed for applications with remotely located indoor air handler units See Air Handlers tab section for unit data Units shipped completely factory assembled piped and wired Each unit is test opera...

Page 3: ...th uniform suction flow constant discharge flow and high volumetric efficiency and quiet operation Compressor consists of two involute spiral scrolls matched together to generate a series of crescent...

Page 4: ...requiring input for indicator lights Outdoor Thermostat Kit An outdoor thermostat can be used to lock out some of the electric heating elements on indoor units where two stage control is applicable Ou...

Page 5: ...Accessories For Touchscreen Thermostat Locking cover clear C0MISC15AE1 1 Remote sensors for C0STAT02AE1L can be applied in the following combinations 1 C0SNZN01AE1 2 C0SNZN73AE1 2 C0SNZN01AE1 and 1 C...

Page 6: ...91 50 123 49 5 Power Factor 96 88 96 87 96 88 Outdoor Fan Motor Full Load Amps 1 1 55 1 7 82 1 8 9 Fan Motor Locked Rotor Amps 1 9 1 1 4 1 2 2 2 9 2 3 OPTIONAL ACCESSORIES must be ordered extra Compr...

Page 7: ...es adjacent to the control box Clearance to one of the other three sides must be 36 in 914 mm Clearance to one of the remaining two sides may be 12 in 305 mm and the final side may be 6 in 152 mm A cl...

Page 8: ...3 4 70 A ELECTRICAL INLETS LIQUID LINE CONNECTION TOP VIEW BASE SECTION 4 3 8 111 COMPRESSOR COIL DRAIN OUTLETS Around perimeter of base OPTIONAL UNIT STAND OFF KIT 4 Field Installed B C A OPTIONAL U...

Page 9: ...3 19A 2 CX34 25A 6F C33 25A 2 CX34 25B 6F C33 25B 2 CX34 30A 6F C33 30A 2 CX34 30B 6F C33 30B 2 CX34 30C 6F C33 30C 2 CX34 31A 6F C33 31A 2 CX34 31B 6F C33 31B 2 CX34 36A 6F C33 36A 2 CX34 36B 6F C33...

Page 10: ...25 3 66 2 52 CR33 30 36B F 4 G60DFV 36B 090 2 56J19 34 600 33 400 20 800 13 00 11 00 8 20 7 20 3075 2695 2435 3 64 2 50 CR33 30 36C F 4 G61MPV 36C 090 2 56J19 34 600 33 200 20 600 13 00 11 00 7 70 7 0...

Page 11: ...ls Furnaces Down Flow Coils Furnaces 49 000 47 500 30 200 13 00 11 00 7 70 7 50 4400 3685 3440 3 78 2 58 CR33 50 60C F 4 G60DFV 60C 110 2 56J20 49 000 47 500 30 400 13 00 11 00 7 70 7 40 4450 3760 351...

Page 12: ...50 CR33 50 60C F 4 G60DFV 60C 090 2 56J20 54 000 55 000 35 600 13 00 11 00 7 70 6 70 4910 4670 4145 3 46 2 52 CR33 60D F 4 G60DFV 60D 135 2 56J20 Horizontal Indoor Coils Furnaces Horizontal Coils Fur...

Page 13: ......

Page 14: ......

Page 15: ...REVISIONS Sections Description of Change Ratings Revised TPA060 ratings...

Page 16: ...tment to quality Specifications Ratings and Dimensions subject to change without notice and without incurring liability Improper installation adjustment alteration service or maintenance can cause pro...

Reviews: