Table 5. Lennox Smart Air Quality Monitor Alert Codes
Alert
ID
Source
device
Causing
Alert
Alert Code
Message
Priority
Condition
Troubleshooting
Clear Condition
80001
Thermostat
IAQ: Persistent
Poor Air Quality
Information
only Dealer
Cycle power to device. To cycle
power, remove device from the wall
and disconnect the
R
terminal and
then reconnect.
• If cycling power does not resolve
the issue, check all installed
Indoor Air Quality (IAQ) equipment
installed in the HVAC system. For
example check:
»
All installed IAQ equipment are
power on, connected and working
properly.
»
HC air filters and replace if dirty.
»
PureAir or PureAir
S
UV lamp and
if not working replace. Check filter
and replace if dirty.
»
ERV/HRV filter and replace if dirty.
»
UV Germicidal lamp is working
and replace if necessary.
If cycling power and checking
all installed IAQ equipment
does not resolve the issue,
then replace the
SAQM
.
Automatically clears when
the system detects that the