11
For drywall applications insert provided wall anchors in holes
until flush with wall and then back out for proper height for mounting.
Screw depth adjustments may be required in order to
accommodate a snug fit for the Smart Air Quality Monitor when
attaching to the wall.
Terminal Designations and Wiring
Recommendations
Use standard thermostat wiring and a field-provided
24VAC transformer (10P17) or 24VAC wall adapter
(18M13) to make the power connections as
exampled in the following illustration.
Table 3. Terminal Designations and Wiring
Recommendations
Terminal
Designation Thermostat Wiring
R
(24VAC
input)
C
(24VAC
return)
Use 18-24AWG non-shielded thermostat wiring
for
R
and
C
connections
Powering the Smart Air Quality Monitor
The following are considerations concerning
powering the SAQM.
• Recommend connecting SAQM to the S40 using
the provided splicing connectors. Both devices
will be powered by the indoor unit transformer
as long as no other equipment is attached
(see
"Figure 4. Using Indoor Unit Power and
Connecting at Thermostat" on page 12)
.
• If additional equipment other than the S40
and SAQM are connected to the indoor unit
transformer then an additional transformer is
required.