2019
SGH120 SHOWN
IMPORTANT
Supply air VFD motor rotation is controlled indepen
dently from scroll compressor rotation. See Cooling
Start-Up section for correct compressor rotation.
Compressor damage due to improper rotation is the
responsibility of the installer.
Table of Contents
Dimensions
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Parts Arrangements
. . . . . . . . . . . . . . . . . . . . . . . . .
Shipping and Packing List
. . . . . . . . . . . . . . . . . . . .
General
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safety
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Unit Support
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Duct Connection
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rigging Unit For Lifting
. . . . . . . . . . . . . . . . . . . . . . .
Condensate Drains
. . . . . . . . . . . . . . . . . . . . . . . . . .
Gas Piping
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pressure Test Gas Piping
. . . . . . . . . . . . . . . . . . . . .
RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE
INSTALLATION
INSTRUCTIONS
SGH/SCH036
(3 TON)
SGH/SCH060
(5 TON)
SGH/SCH120
(10 TON)
SGH/SCH240
(20 TON)
ROOFTOP UNITS
507964-01
9/2019
Supersedes 507364-02
High Altitude Derate
. . . . . . . . . . . . . . . . . . . . . . . . .
Optional Outdoor Air Hood
. . . . . . . . . . . . . . . . . . . .
Electrical Connections
. . . . . . . . . . . . . . . . . . . . . . .
Blower Operation and Adjustments
. . . . . . . . . . . .
Cooling Start-Up
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cooling Operation and Adjustments
. . . . . . . . . . . .
Gas Heat Start-Up
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Electric Heat Start-Up
. . . . . . . . . . . . . . . . . . . . . . . .
Heating Operation and Adjustments
. . . . . . . . . . . .
MSAV
t
Unit Start-Up
. . . . . . . . . . . . . . . . . . . . . . . .
MSAV
t
Operation
. . . . . . . . . . . . . . . . . . . . . . . . . .
Direct Drive Start-Up
. . . . . . . . . . . . . . . . . . . . . . . . .
Hot Gas Reheat Startup
. . . . . . . . . . . . . . . . . . . . . .
Economizer Start-Up
. . . . . . . . . . . . . . . . . . . . . . . . .
Service
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Factory Control Parameter Settings
. . . . . . . . . . . .
Start-Up Report
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, person
al injury or loss of life. Installation and service must
be performed by a licensed professional HVAC in
staller or equivalent, service agency, or the gas sup
plier
WHAT TO DO IF YOU SMELL GAS:
If the information in this manual is not
followed exactly, a fire or explosion
may result causing property damage,
personal injury or loss of life.
WARNING
Do not store or use gasoline or
other flammable vapors and liq
uids in the vicinity of this or any
other appliance.
Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
S
Do not try to light any appliance.
S
Extinguish any open flame.
S
Do not touch any electrical switch; do not
use any phone in your building.
S
Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli
er's instructions.
S
If you cannot reach your gas supplier, call
the fire department.
S
Leave the building immediately.