Page 3
GAS HEAT ACCESSORIES
Input
High Altitude
Pressure Switch Kit
Natural Gas to
LPG/Propane Kit
LPG/Propane
to Natural Gas Kit
Natural Gas
High Altitude
Orifice Kit
4501 - 7500 ft.
7501 - 10,000 ft.
0 - 7500 ft.
0 - 7500 ft.
7501- 10,000 ft.
all models
74W90
74W91
69W73
73W81
73W37
OPTIONAL ACCESSORIES - MUST BE ORDERED EXTRA
“B” Width
Models
“C” Width
Models
“D” Width
Models
CABINET ACCESSORIES
Horizontal Suspension Kit - Horizontal only
51W10
51W10
51W10
Return Air Base - Upflow only
50W98
50W99
51W00
CONDENSATE DRAIN KITS
Condensate Drain Heat Cable
6 ft.
26K68
26K68
26K68
24 ft.
26K69
26K69
26K69
50 ft.
26K70
26K70
26K70
Heat Cable Tape
Fiberglass - 1/2 in. x 66 ft.
36G53
36G53
36G53
Aluminum foil - 2 in. x 60 ft.
16P89
16P89
16P89
Crawl Space Vent Drain Kit
51W18
51W18
51W18
CONTROLS
Twinning Kit
65W80
65W80
65W80
FILTER KITS
1
Air Filter and
Rack Kit
Horizontal (end)
Size of filter - in.
87L96
- 18 x 25 x 1
87L97
- 20 x 25 x 1
87L98
- 25 x 25 x 1
Side Return
Single
44J22
44J22
44J22
Ten Pack
66K63
66K63
66K63
Size of filter - in.
16 x 25 x 1
16 x 25 x 1
16 x 25 x 1
NIGHT SERVICE KITS
Night Service Kit
51W03
51W03
51W03
TERMINATION KITS
See Installation Instructions for specific venting information.
Termination Kits -
Direct Vent
Applications Only
Concentric
US - 2 in.
71M80
69M29
- - -
3 in.
- - -
60L46
60L46
Canada - 2 in.
44W92
44W92
- - -
3 in.
- - -
44W93
44W93
Flush-Mount
2, 2-1/2 or 3 in.
51W11
51W11
51W11
Wall - Close
Couple
US - 2 in.
22G44
- - -
- - -
3 in.
44J40
44J40
44J40
Wall - Close
Couple WTK
Canada - 2 in.
30G28
- - -
- - -
3 in.
81J20
81J20
81J20
Termination Kits -
Direct or Non-
Direct vent
Roof
2 in.
15F75
15F75
- - -
Wall Ring Kit
2 in.
15F74
3
15F74
- - -
Roof Termination Flashing Kit - Direct or
Non-Direct Vent (2 flashings)
2 in.
44J41
44J41
44J41
1
Cleanable polyurethane frame type filter.
2
Kits contain enough parts for two, non−direct vent installations.
3
Non−direct vent only.
NOTE - Termination Kits
44W92
,
44W93
,
30G28
,
81J20
are certified to ULC S636 standard for use in Canada only.
INSTALLATION CLEARANCES - INCHES (MM)
Sides
1
0 inches (0 mm)
Rear
0 inches (0 mm)
Top/Plenum
1 inch (25 mm)
Front
0 inches (0 mm)
Front (service/alcove)
24 inches (610 mm)
Floor
2
Combustible
NOTE − Air for combustion must conform to the methods outlined in the National Fuel Gas Code (NFPA 54/ANSI−Z223.1)
or the National Standard of Canada CAN/CSA−B149.1 Natural Gas and Propane Installation Code”.
NOTE − In the U.S. flue sizing must conform to the methods outlined in the current National Fuel Gas Code (NFPA 54/
ANSI−Z223.1) or applicable provisions of local building codes. In Canada flue sizing must conform to the methods
outlined in National Standard of Canada CAN/CSA−B149.1.
1
Allow proper clearances to accommodate condensate trap and vent pipe installation.
2
Do not install the furnace directly on carpeting, tile, or other combustible materials other than wood flooring.