iComfort Wi-Fi
®
7-Day Programmable Communicating Thermostat
Page 7
Parameter Name:
Increment
Parameter Value Setting
Default
Balance Point Control
Disabled
Disabled or Enabled
—
Min HP heating demand
30
30 to 100ºF
5
Humiditrol Comfort Adjust
Maximum
Overcooling
Maximum, Minimum and Midpoint
Overcooling
—
Humidification Control Mode
Basic
Display Only, Precision, Precision Dew Point
Control, Basic, Basic Dew Point Control
—
Max Humidification Setpoint
45ºF
15 to 45ºF
1ºF
Auto Changeover - Humidif. Dead-band
5ºF
5 to 10ºF
1ºF
Humiditrol and Aux Dehum Min Run Time
15 minutes
5 to 30 minutes
5 minutes
HP Heating Lockout Time
120 minutes
60 to 240 minutes
30 minutes
Heat Cool Stages Locked In
Disabled
Enabled, Disabled
—
*1st Stage Differential
1.0ºF
0.5 to 3ºF
0.5ºF
*2nd Stage Differential
1.0ºF
0.5 to 8ºF
0.5ºF
*3nd Stage Differential
1.0ºF
0.5 to 8ºF
0.5ºF
Stage Delay Timers
Enabled
Enabled, Disabled
—
*2nd Stage Delay
20 Minutes
5 to 120 Minutes
5 Min
*3rd Stage Delay
20 Minutes
5 to 120 Minutes
5 Min
Min De-humidification Setpoint
40
40 to 60 RH%
1
Outdoor Temperature Reading Calibration
0ºF
-10 to 10ºF
1ºF
Zoning Gas heating DAT Cool down Target
100ºF
80 to 110ºF
1ºF
Zoning Anticipated Discharge Air Temperature Adjustment
60ºF
0 to 120ºF
10ºF
Zoning Target Supply Air Temp for Cooling
50ºF
50 to 60ºF
1ºF
Zoning Target Supply Air Temp for Gas/Electric Heating
100ºF
100 to 130ºF
5ºF
Zoning Target Supply Air Temp for HP Heating
90ºF
85 to 110ºF
1ºF
Zoning Supply Air Temp Limit for Cooling
40ºF
35 to 45ºF
2ºF
Zoning Supply Air Temp Limit for Gas/Electric Heating
140ºF
140 to 160ºF
5ºF
*Number of stages shown in thermostat is dependent on equipment that is installed. Electric heat will bring on 2 elements at a time if available.
Lock in 2nd stage HP by Outdoor Temp
Off
Off, 40ºF (4ºC), 45ºF (7ºC), 50ºF (10ºC), 55ºF
(13ºC)
—
Zone 1 First Stage Differential
1.0ºF
0.5 to 3.0ºF
0.5ºF
Zone 2 First Stage Differential
1.0ºF
0.5 to 3.0ºF
0.5ºF
Zone 3 First Stage Differential
1.0ºF
0.5 to 3.0ºF
0.5ºF
Zone 4 First Stage Differential
1.0ºF
0.5 to 3.0ºF
0.5ºF
Zone 1 Continuous Blower CFM
To be determine by equipment capacity.
Zone 2 Continuous Blower CFM
Zone 3 Continuous Blower CFM
Zone 4 Continuous Blower CFM
Zone 1 Cooling CFM
Zone 2 Cooling CFM
Zone 3 Cooling CFM
Zone 4 Cooling CFM
Zone 1 Heating CFM
Zone 2 Heating CFM
Zone 3 Heating CFM
Zone 4 Heating CFM
Table 3. System Devices > Air Conditioner
system devices
System
Air Conditioner
Furnace
Thermostat
To adjust a setting,
highlight it, then press
Edit
edit
next
back
about
resetAll
Air Conditioner
Parameter Name:
Default
Parameter Value Setting
Increment
Equipment Name
Outdoor Unit
(keyboard input screen = up to 35 characters in string)
—
Compressor Short Cycle Delay
300 Seconds
60 to 300 Seconds
60 Sec
High Normal Cooling Airflow (XC25 only)
1600
450 to 2150
25
Low Normal Cooling Airflow (XC25 only)
750
450 to 2150
25
Dehum Airflow Adjustment Adder
0
0 to 30
1