FTF8 VERTICAL ELEVATION CHART

Height Of

Number Of FTF8

Chimney Only

Chimney Lengths

Inches

Feet/Inches

12" 18"

36" 48"

Height Of

Number Of FTF8

Chimney Only

Chimney Lengths

Inches

Feet/Inches

12" 18"

36" 48"

386

¹⁄₂

32

2

¹⁄₂

0

1

0

8

390

³⁄₄

32

6

³⁄₄

2

0

0

8

396

³⁄₄

33

0

³⁄₄

1

1

0

8

404

¹⁄₂

33

8

¹⁄₂

0

0

1

8

414

³⁄₄

34

6

³⁄₄

1

0

1

8

416

¹⁄₂

34

8

¹⁄₂

0

0

0

9

420

³⁄₄

35

0

³⁄₄

0

1

1

8

426

³⁄₄

35

6

³⁄₄

1

0

0

9

432

³⁄₄

36

0

³⁄₄

0

1

0

9

437

36

5

2

0

0

9

443

36 11

1

1

0

9

450

³⁄₄

37

6

³⁄₄

0

0

1

9

461

38

5

1

0

1

9

462

³⁄₄

38

6

³⁄₄

0

0

0

10

466

³⁄₄

38 10

³⁄₄

0

1

1

9

472

³⁄₄

39 4

³⁄₄

1

0

0

10

478

³⁄₄

39 10

³⁄₄

0

1

0

10

483

40

3

2

0

0

10

489

40

9

1

1

0

10

496

³⁄₄

41

4

³⁄₄

0

0

1

10

507

42

3

1

0

1

10

508

³⁄₄

42

4

³⁄₄

0

0

0

11

513

42

9

0

1

1

10

519

43

3

1

0

0

11

525

43

9

0

1

0

11

529

¹⁄₄

44

1

¹⁄₄

2

0

0

11

535

¹⁄₄

44

7

¹⁄₄

1

1

0

11

543

45

3

0

0

1

11

553

¹⁄₄

46

1

¹⁄₄

1

0

1

11

555

46

3

0

0

0

12

559

¹⁄₄

46

7

¹⁄₄

0

1

1

11

565

¹⁄₄

47

1

¹⁄₄

1

0

0

12

571

¹⁄₄

47

5

¹⁄₄

0

1

0

12

575

¹⁄₂

47 11

¹⁄₂

2

0

0

12

581

¹⁄₂

48

5

¹⁄₂

1

1

0

12

589

¹⁄₄

49

1

¹⁄₄

0

0

1

12

599

¹⁄₂

49 11

¹⁄₂

1

0

1

12

601

¹⁄₄

50

1

¹⁄₄

0

0

0

13

605

¹⁄₂

50

5

¹⁄₂

0

1

1

12

611

¹⁄₂

51 11

¹⁄₂

1

0

0

13

617

¹⁄₂

51

5

¹⁄₂

0

1

0

13

621

¹⁄₂

51

9

¹⁄₂

2

0

0

13

627

¹⁄₂

52

3

¹⁄₂

1

1

0

13

635

¹⁄₂

52 11

¹⁄₂

0

0

1

13

645

¹⁄₂

53

9

¹⁄₂

1

0

1

13

647

¹⁄₂

53 11

¹⁄₂

0

0

0

14

651

¹⁄₂

54

3

¹⁄₂

0

1

1

13

657

¹⁄₂

54

9

¹⁄₂

1

0

0

14

663

¹⁄₂

55

3

¹⁄₂

0

1

0

14

667

³⁄₄

55

7

³⁄₄

2

0

0

14

673

³⁄₄

56

1

³⁄₄

1

1

0

14

681

¹⁄₂

56

9

¹⁄₂

0

0

1

14

691

³⁄₄

57

7

³⁄₄

1

0

1

14

693

¹⁄₂

57

9

¹⁄₂

0

0

0

15

697

³⁄₄

58

1

³⁄₄

0

1

1

14

703

³⁄₄

58

7

³⁄₄

1

0

0

15

709

³⁄₄

59

1

³⁄₄

0

1

0

15

714

59

6

2

0

0

15

720

60

0

1

1

0

15

727

³⁄₄

60

7

³⁄₄

0

0

1

15

738

61

6

1

0

1

15

739

³⁄₄

61

7

³⁄₄

0

0

0

16

744

62

0

0

1

1

15

11

0 11

1

0

0

0

17

1

5

0

1

0

0

21

¹⁄₄

1

9

¹⁄₄

2

0

0

0

27

¹⁄₄

2

3

¹⁄₄

1

1

0

0

35

2 11

0

0

1

0

47

3 11

0

0

0

1

51

¹⁄₄

4

3

¹⁄₄

0

1

1

0

57

¹⁄₄

4

9

¹⁄₄

1

0

0

1

63

¹⁄₄

5

3

¹⁄₄

0

1

0

1

67

¹⁄₄

5

7

¹⁄₄

2

0

0

1

73

¹⁄₄

6

1

¹⁄₄

1

1

0

1

81

¹⁄₄

6

9

¹⁄₄

0

0

1

1

93

¹⁄₄

7

9

¹⁄₄

0

0

0

2

97

¹⁄₄

8

1

¹⁄₄

0

1

1

1

102

¹⁄₂

8

6

¹⁄₂

1

0

0

2

109

¹⁄₄

9

1

¹⁄₄

0

1

0

2

113

¹⁄₂

9

5

¹⁄₂

2

0

0

2

119

¹⁄₂

9 11

¹⁄₂

1

1

0

2

127

¹⁄₄

10

7

¹⁄₄

0

0

1

2

137

¹⁄₂

11

5

¹⁄₂

1

0

1

2

139

¹⁄₄

11

7

¹⁄₄

0

0

0

3

143

¹⁄₂

11 11

¹⁄₂

0

1

1

2

149

¹⁄₂

12

5

¹⁄₂

1

0

0

3

155

¹⁄₂

12 11

¹⁄₂

0

1

0

3

159

³⁄₄

13

3

³⁄₄

2

0

0

3

165

³⁄₄

13

9

³⁄₄

1

1

0

3

173

¹⁄₂

14

5

¹⁄₂

0

0

1

3

183

³⁄₄

15

3

³⁄₄

1

0

1

3

185

¹⁄₂

15

5

¹⁄₂

0

0

0

4

189

³⁄₄

15

9

³⁄₄

0

1

1

3

195

³⁄₄

16

3

³⁄₄

1

0

0

4

201

³⁄₄

16

9

³⁄₄

0

1

0

4

206

17

2

2

0

0

4

212

17

8

1

1

0

4

219

³⁄₄

18

3

³⁄₄

0

0

1

4

230

19

2

1

0

1

4

231

³⁄₄

19

3

³⁄₄

0

0

0

5

236

19

8

0

1

1

4

242

20

2

1

0

0

5

248

20

8

0

1

0

5

252

21

0

2

0

0

5

258

21

6

1

1

0

5

266

22

2

0

0

1

5

276

23

0

1

0

1

5

278

23

2

0

0

0

6

282

23

6

0

1

1

5

288

24

0

1

0

0

6

294

³⁄₄

24

6

³⁄₄

0

1

0

6

298

¹⁄₄

24 10

¹⁄₄

2

0

0

6

304

¹⁄₄

25

4

¹⁄₄

1

1

0

6

312

26

0

0

0

1

6

322

¹⁄₄

26 10

¹⁄₄

1

0

1

6

324

27

0

0

0

0

7

328

¹⁄₄

27

4

¹⁄₄

0

1

1

6

334

¹⁄₄

27 10

¹⁄₄

1

0

0

7

340

¹⁄₄

28

4

¹⁄₄

0

1

0

7

344

¹⁄₂

28

8

¹⁄₂

2

0

0

7

350

¹⁄₂

29

2

¹⁄₂

1

1

0

7

358

¹⁄₄

29 10

¹⁄₄

0

0

1

7

368

¹⁄₂

30

8

¹⁄₂

1

0

1

7

370

¹⁄₄

30 10

¹⁄₄

0

0

0

8

374

¹⁄₂

31

2

¹⁄₂

0

1

1

7

380

¹⁄₂

31

8

¹⁄₂

1

0

0

8

The offset and return elbows may be attached
together, or a section or sections of chimney
may be used between, but do not exceed 20' in
total length between elbows. If sections of pipe
exceed 10' between elbows, a chimney stabi-
lizer must be used at the midpoint (

Figure 36 ).

The stabilizer support straps must be attached
under tension (in shear) to structural framing
members above. When two sets of elbows are
used, the maximum combined length of chim-
ney used between elbows cannot exceed 20'
(

Figure 37 ). Example: If C

1

 = 10' then C

2

 cannot

exceed 10'.

If an offset exceeds 6' in length, each chimney
joint beyond the first 6' of offset to the return
elbow, must be secured by a No. 8 x 

¹⁄₂

" sheet

metal screw located at the underside of the joint
(

Figure 38 ).

¹⁄₈

" diameter hole must be drilled in the

chimney joint using a 

¹⁄₈

" diameter drill. Hole

should be drilled in center of joint overlap
(

Figure 39 ). Be sure to drill only through the

outer chimney casting. Do not puncture the
inner flue.

Maximum offset of chimney system is 30

°

. Two

offsets must not be assembled to form a 60

°

offset. However, two sets of offset and return
elbows may be used on a single flue system,
provided the total height of the system exceeds
25'.

Return elbow support straps must be securely
attached under tension (in shear) to structural
framing members above. Do not substitute a
FTF8-30 offset elbow in place of a FTF8-E30
return elbow.

OFFSET CALCULATIONS

Step 1. Use Offset Chart to determine amount
of horizontal offset (A) and height (B) for vari-
ous chimney section assemblies.

Step 2. Use “Height of Chimney Only” column
in The Vertical Elevation Chart to determine
combinations of chimney used above return
elbow to achieve desired heights. Reference
Components Effective Height Chart in vertical
elevation chart section.

Step 3. Use Elevation Chart as job estimator
only. Add necessary firestop spacers and sta-
bilizers as required. Firestop spacers must be
used as shown in 

Figures 22 and 23 and

stabilizers as shown in 

Figure 28.

Summary of Contents for HC-42

Page 1: ...modify the fireplace or its components under any circumstances Any modification or alteration of the fireplace system including but not limited to the fireplace chimney components and accessories may...

Page 2: ...damage as a result of handling or transporta tion These items should be inspected by your distributor or qualified factory representative to ensure safe condition When in doubt con sult your distribu...

Page 3: ...These fireplace systems are designed for in stallation in accordance with the National Fire Protection Standard for chimneys fireplaces and solid fuel burning appliances NFPA 211 and in accordance wit...

Page 4: ...overhead obstructions such as trees power lines etc A chase should be constructed and insulated just like any outside wall In a cold climate we recommend the base of the chase should also be insulate...

Page 5: ...l safety strips beneaththefireplaceasillustrated Figures6 7 and 8 The safety strips should overlap for continual coverage of the floor Note Safety strips are not required when fire place rests on a no...

Page 6: ...ce If a wall covering such as drywall is to be attached to the rear wall then the 23 606 mm must be measured from the drywall surface It is important that this dimension be exact If the appliance is t...

Page 7: ...der Fireplace Framing B A A Outside Chase G H Back Wall of Chase Enclosure Including Finising Materials if any Rough Framing Face Unfinished Shown FOAK Combustion Air Kit Optional Corner Installation...

Page 8: ...upthroughtheceiling or floor joists to an outside wall The air duct s inlet should be located above any anticipated snow level Note If the fireplace is installed against an inside wall the Class 0 me...

Page 9: ...sure proper engagement Checkverticalalignmentofchim ney so that it projects from the roof in true vertical position Figure 27 Step 4 Note Chimney sections are con structed with a unique locking tab de...

Page 10: ...Do not overtighten as this might dam age the chimney section refer to Figure 31 Note If chimney extends more than 8 above roof surface guy wires are also recommended Use three 3 guy wires attach to l...

Page 11: ...fireplace system is 15 0 The maxi mum height is 60 0 To determine the number of chimney sections and chimney components required follow these steps 1 Determine total vertical height of the fireplace i...

Page 12: ...23 0 1 0 1 5 278 23 2 0 0 0 6 282 23 6 0 1 1 5 288 24 0 1 0 0 6 294 24 6 0 1 0 6 298 24 10 2 0 0 6 304 25 4 1 1 0 6 312 26 0 0 0 1 6 322 26 10 1 0 1 6 324 27 0 0 0 0 7 328 27 4 0 1 1 6 334 27 10 1 0 0...

Page 13: ...35 69 1 0 0 1 0 1 37 73 1 0 0 2 1 0 38 75 1 0 0 0 2 0 39 77 1 0 2 1 1 0 41 80 1 0 1 4 0 0 43 83 1 0 1 0 2 0 44 85 1 0 0 0 1 1 45 87 1 0 0 3 1 0 46 89 1 0 0 1 2 0 48 91 1 0 2 0 2 0 49 94 1 0 1 0 1 1 50...

Page 14: ...mney section Step 2 Center inner slip section into inner flue pipe slip down Step 3 Center outer locking section over outer chimneypipe Pushdownuntillockingjointhas firmly engaged Step 4 Pull up sligh...

Page 15: ...per operation before completing any enclo sure around the firebox Failure to do so may result in extensive and costly rework Locate the actuator arm along the right side of the appliance firebox openi...

Page 16: ...LACE IF THE FIREPLACE HAS BEEN FACED WITHNONCOMBUSTIBLEMATERIALS THERE MIGHT NOT BE SUFFICIENT CLEARANCE TO INSTALL THE GLASS DOORS OF YOUR CHOICE ENSURE ADEQUATE CLEARANCE IS MAINTAINED AT ALL TIMES...

Page 17: ...5 6 56 6 1 2 Wonderboard 3 23 31 7 51 7 1 2 Super Firetemp M Johns Manville 61 1 64 1 42 1 3 8 Super Firetemp L Johns Manville 54 1 85 Face brick 9 00 111 20 93 20 7 8 Common brick 5 00 20 Cement mort...

Page 18: ...ptable combinations of materialsbecause Rvalues areadditivewhere r and k values are not R value 1 k r x thickness of material used Example Given that the required R value for a suitable floor protecto...

Page 19: ...Chase Termination Square 63L48 FTF8 CT1 Firestop Spacer Flat 63L31 F8FS 2 Locking Band 63L60 FLB Forced Air Blower Kits Single Speed 80L84 FBK 100 Variable Speed 80L85 FBK 200 FBK 200 Models Only Outs...

Page 20: ...ign materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information 1110 West Taft Avenue Orange CA 92865 Chase Termina...

Reviews: