NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

11

Figure 34

Note: It is recommended that all exterior ex-
posed metal fireplace components; such as
terminations, flashings, storm collars and/or
flue be painted with a premium quality, high
temperature, rust preventative paint designed
for metal. This is especially important when
installations are made in abnormally adverse or
corrosive environments; such as near lakes,
oceans or in areas with consistently high hu-
midity conditions. Consult the paint manufac-
turers instructions for proper preparation and
application.

TEN FOOT RULE SUMMARY

The minimum chimney height above the roof
and/or to adjacent walls and buildings is speci-
fied by all major building codes.

If the horizontal distance from the peak of the
roof is less then 10', the top of the chimney
must be at least 2' above the peak of the roof.

If the horizontal distance from the chimney
edge to the peak of the roof is more than 10' a
chimney height reference point is established
on the roof surface 10' horizontally from the
chimney edge. The top of the chimney must be
at least 2' above this reference point. In all
cases, the chimney cannot be less then 3'
above the roof at the edge of the chimney.

The 2' in 10' rule is necessary in the interest of
safety but does not ensure smoke-free opera-
tion. Trees, buildings, adjoining roof lines, ad-
verse wind conditions, etc., may require a taller
chimney should the fireplace not draft properly
(

see Figure 34 ).

Figure 35

This suggestion is provided in the interest of
better operation. If the terminations are located
too close to each other, smoke may migrate
from one flue into the other.

FTF8 CHIMNEY COMPONENT
CALCULATIONS

The minimum installed height of the com-
pleted fireplace system is 15' 0". The maxi-
mum height is 60' 0".

To determine the number of chimney sections
and chimney components required, follow
these steps:

1. Determine total vertical height of the fireplace
installation. This dimension is the distance from
the surface the fireplace sets on to the point
where smoke exits from the termination.

2. Determine the number of chimney compo-
nents required, except chimney sections. This
would include firestop spacers, stabilizers, roof
flashing, etc.

3. The effective heights of the components are:

The Fireplace

=

45 

³⁄₈

"

FTF8-12

=

10 

¹⁄₄

"

FTF8-18

=

16 

¹⁄₄

"

FTF8-36

=

34 

¹⁄₄

"

FTF8-48

=

46 

¹⁄₄

"

FTF8-CTD Termination

=

4"

FTF8-CT1 Termination

=

12" to 18"

FTF8-CT2 Termination

=

15" to 23"

FTF8-CTDT Termination

=

12" to 18"

FTF8-CTT Termination

=

6" to 14"

FTF8-ATT Termination

=

8" to 14"

FTF8-S4 Stabilizer *

=

3"*

* Required for every 30' of vertical chimney
and/or 10' of offset chimney.

4. Determine amount of chimney height re-
quired by subtracting total combined height of
all pre-selected components (fireplace and
chimney components from total desired height.)

Reference Vertical Elevation Chart and deter-
mine the number of chimney sections (quantity
and length) required.

SPECIAL OFFSET INSTRUCTIONS

To clear any overhead obstructions, you may
offset your chimney system using Security's
30

°

 offset and return elbows. Use two elbows -

an offset elbow to initiate the offset and a return
elbow to terminate it. A 30

°

 offset elbow, an-

gling in any direction, may be the first compo-
nent used off the top of the fireplace flue collar.

CTD

18"

18"

24"

24"

CTDT

CTDT

Less Than 10'

3'

Min

2' Min.

10'

3'

Min

MULTIPLE TERMINATIONS

If more than one termination is located in the
same chase or within the same general proxim-
ity, we suggest they should be separated in
distance at least 24" horizontally from flue cen-
ter to flue center and stacked or staggered
vertically at least 18" apart, from the termina-
tion of one smoke exit to the termination of
another smoke exit (

Figure 35 ).

Summary of Contents for HC-42

Page 1: ...modify the fireplace or its components under any circumstances Any modification or alteration of the fireplace system including but not limited to the fireplace chimney components and accessories may...

Page 2: ...damage as a result of handling or transporta tion These items should be inspected by your distributor or qualified factory representative to ensure safe condition When in doubt con sult your distribu...

Page 3: ...These fireplace systems are designed for in stallation in accordance with the National Fire Protection Standard for chimneys fireplaces and solid fuel burning appliances NFPA 211 and in accordance wit...

Page 4: ...overhead obstructions such as trees power lines etc A chase should be constructed and insulated just like any outside wall In a cold climate we recommend the base of the chase should also be insulate...

Page 5: ...l safety strips beneaththefireplaceasillustrated Figures6 7 and 8 The safety strips should overlap for continual coverage of the floor Note Safety strips are not required when fire place rests on a no...

Page 6: ...ce If a wall covering such as drywall is to be attached to the rear wall then the 23 606 mm must be measured from the drywall surface It is important that this dimension be exact If the appliance is t...

Page 7: ...der Fireplace Framing B A A Outside Chase G H Back Wall of Chase Enclosure Including Finising Materials if any Rough Framing Face Unfinished Shown FOAK Combustion Air Kit Optional Corner Installation...

Page 8: ...upthroughtheceiling or floor joists to an outside wall The air duct s inlet should be located above any anticipated snow level Note If the fireplace is installed against an inside wall the Class 0 me...

Page 9: ...sure proper engagement Checkverticalalignmentofchim ney so that it projects from the roof in true vertical position Figure 27 Step 4 Note Chimney sections are con structed with a unique locking tab de...

Page 10: ...Do not overtighten as this might dam age the chimney section refer to Figure 31 Note If chimney extends more than 8 above roof surface guy wires are also recommended Use three 3 guy wires attach to l...

Page 11: ...fireplace system is 15 0 The maxi mum height is 60 0 To determine the number of chimney sections and chimney components required follow these steps 1 Determine total vertical height of the fireplace i...

Page 12: ...23 0 1 0 1 5 278 23 2 0 0 0 6 282 23 6 0 1 1 5 288 24 0 1 0 0 6 294 24 6 0 1 0 6 298 24 10 2 0 0 6 304 25 4 1 1 0 6 312 26 0 0 0 1 6 322 26 10 1 0 1 6 324 27 0 0 0 0 7 328 27 4 0 1 1 6 334 27 10 1 0 0...

Page 13: ...35 69 1 0 0 1 0 1 37 73 1 0 0 2 1 0 38 75 1 0 0 0 2 0 39 77 1 0 2 1 1 0 41 80 1 0 1 4 0 0 43 83 1 0 1 0 2 0 44 85 1 0 0 0 1 1 45 87 1 0 0 3 1 0 46 89 1 0 0 1 2 0 48 91 1 0 2 0 2 0 49 94 1 0 1 0 1 1 50...

Page 14: ...mney section Step 2 Center inner slip section into inner flue pipe slip down Step 3 Center outer locking section over outer chimneypipe Pushdownuntillockingjointhas firmly engaged Step 4 Pull up sligh...

Page 15: ...per operation before completing any enclo sure around the firebox Failure to do so may result in extensive and costly rework Locate the actuator arm along the right side of the appliance firebox openi...

Page 16: ...LACE IF THE FIREPLACE HAS BEEN FACED WITHNONCOMBUSTIBLEMATERIALS THERE MIGHT NOT BE SUFFICIENT CLEARANCE TO INSTALL THE GLASS DOORS OF YOUR CHOICE ENSURE ADEQUATE CLEARANCE IS MAINTAINED AT ALL TIMES...

Page 17: ...5 6 56 6 1 2 Wonderboard 3 23 31 7 51 7 1 2 Super Firetemp M Johns Manville 61 1 64 1 42 1 3 8 Super Firetemp L Johns Manville 54 1 85 Face brick 9 00 111 20 93 20 7 8 Common brick 5 00 20 Cement mort...

Page 18: ...ptable combinations of materialsbecause Rvalues areadditivewhere r and k values are not R value 1 k r x thickness of material used Example Given that the required R value for a suitable floor protecto...

Page 19: ...Chase Termination Square 63L48 FTF8 CT1 Firestop Spacer Flat 63L31 F8FS 2 Locking Band 63L60 FLB Forced Air Blower Kits Single Speed 80L84 FBK 100 Variable Speed 80L85 FBK 200 FBK 200 Models Only Outs...

Page 20: ...ign materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information 1110 West Taft Avenue Orange CA 92865 Chase Termina...

Reviews: