background image

29

ACCESSORIES - MODEL GRANDVIEW™ 230

Secure Temp® Factory-Built Chimney

6” Secure Temp ASHT and Secure Temp G-ASHT

Cat. No.

Model

Description

Pc. / Container

Lengths and Fittings

6L8

6L8

LENGTH 6” X 8” 

1

6L12

6L12

LENGTH 6” X 12” 

1

6L18

6L18

LENGTH 6” X 18” 

1

6L24

6L24

LENGTH 6” X 24” 

1

6L36

6L36

LENGTH 6” X 36” 

1

6L48

6L48

LENGTH 6” X 48” 

1

6LA

6LA

ADJUSTABLE LENGTH, 12” 

1

6TI

6TI

INSULATED TEE (TCS INCLUDED)

1

6TCS

6TCS

INSULATED SS TEE CAP (INCLUDED 

WITH TI)

10

6TB

6TB 

BASE TEE GALVANIZED (TC IN-

CLUDED)

1

6TBS

6TBS 

BASE TEE STAINLESS (TCS IN-

CLUDED)

1

6TBD

6TBD

BASE TEE GALVANIZED DOUBLE (TC 

INCLUDED)

1

6TC

6TC

BASE TEE CAP GALVANIZED

10

6TCI

6TCI

INSULATED TEE CAP (USE WITH 

SME SUPPORT)

5

6TCP

6TCP

DRAIN TEE CAP (USE WITH SME 

SUPPORT)

5

6E15

6E15

INSULATED ELBOW 15 DEGREE

2

6E30

6E30

INSULATED ELBOW 30 DEGREE

1

Aluminum Zinc Coated Steel (Lengths and Fittings)

6GL8 

6GL8

LENGTH 6” X 8” 

1

6GL12

6GL12

LENGTH 6” X 12”

1

6GL18

6GL18

LENGTH 6” X 18”

1

6GL24

6GL24

LENGTH 6” X 24”

1

6GL36

6GL36

LENGTH 6” X 36”

1

6GL48

6GL48

LENGTH 6” X 48”

1

6GLA

6GLA

ADJUSTABLE LENGTH, 12”

1

6GTI

6GTI

INSULATED TEE (TCS INCLUDED)

1

6TCS

6TCS

INSULATED SS TEE CAP (INCLUDED 

WITH GTI)

10

6GE15

6GE15

INSULATED ELBOW 15 DEGREE

2

6GE30

6GE30

INSULATED ELBOW ALUM-ZINC 30 

DEGREE

1

Supports

6UP

6UP

FLUE EXTENSION 

10

PS

PS

SqUARE CATHEDRAL SUPPORT 

EXTENSION 

1

6SSC

6SSC

SqUARE CATHEDRAL SUPPORT W/

COUPLER 

1

6SSAC

6SSAC

ADJUSTABLE SqUARE CATHEDRAL 

SUPPORT w/COUPLER

1

6SFC

6SFC

FINISHING SUPPORT W/COUPLER

1

Cat. No.

Model

Description

Pc. / Container

Supports (continued)

6SM

6SM

TEE SUPPORT

1

6SMA

6SMA

GALVALUME ADJUSTABLE TEE 

SUPPORT (2” TO 6”)

5

SO

SO

OFFSET SUPPORT / WALL SUP-

PORT

10

ST

ST

ROOF SUPPORT

10

6SD

6SD

FLOOR SUPPORT

5

6SP

6SP

ANCHOR PLATE

10

Braces and Firestops

6BF

6BF

FIRESTOP

10

6RSM30

6RSM30 ANGLED FIRESTOP - 30 DEGREE

6RS

6RS

RADIATION SHIELD

5

6RSA2

6RSA2 

2PC INSULATED ATTIC RADIATION 

SHIELD

1

6ARSA

6ARSA

ADJUSTABLE INSULATED ATTIC 

RADIATION SHIELD

1

6RSI

6RSI

INSULATED RADIATION SHIELD

1

6RSM

6RSM

INSULATED WALL THIMBLE

1

6RSMI30 6RSMI30 30-DEGREE RADIATION SHIELD

1

BS2

BS2

UNIVERSAL ROOF BRACE

1

BM

BM

UNIVERSAL WALL BAND

10

6BH

6BH

GUY WIRE BAND (WIRE NOT 

INCLUDED)

10

6FR

6FR

FLAT ROOF FLASHING

3

6FAR

6FAR

ADJUSTABLE ROOF FLASHING - 

1/12- 7/12

3

6FARA

6FARA

ADJUSTABLE MALLEABLE ALUMI-

NUM ROOF FLASHING 1/12 - 7/12

6FBR

6FBR

ADJUSTABLE ROOF FLASHING - 

8/12- 12/12

3

6FBRA

6FBRA

ADJUSTABLE MALLEABLE ALUMI-

NUM ROOF FLASHING 8/12 - 12/12

6FBBR

6FBBR

ADJUSTABLE ROOF FLASHING 

12/12 - 21/12

3

6FPR

6FPR

PEAK ROOF FLASHING 1/12 -7/12

3

6FPBR

6FPBR

PEAK ROOF FLASHING 8/12 -12/12

3

6FC

6FC

STORM COLLAR

10

Chimney Termination

6CC

6CC

RAIN CAP

1

PE

PE

UNIVERSAL SPARK ARRESTER 

BAND

10

Chimney Accessories

6PF

6PF

DECORATIVE TRIM

5

6PB

6PB

DECORATIVE COLLAR

25

6PA

6PA

BLACK PIPE ADAPTOR

1

6PD

6PD

FINISHING CONE

1

Fireplace Components

6EK-1

6EK-1

EXTERIOR KIT (INCLUDES 1 TI, 1 

TCI, 1 SME, 1 RSM, 1 CC, 1 PB, 

1 BM)

1

6IK

6IK

INTERIOR KIT (INCLUDES 1 SFC, 1 

RSA2, 1CC)

1

Pl

an

ni

ng

 In

st

al

la

tio

n

Sa

fe

ty

 a

nd

 G

en

er

al

In

st

al

la

tio

n

Op

er

at

io

n

M

ai

nt

en

an

ce

Tr

ou

bl

es

ho

ot

in

g

Pa

rts

 / 

Ac

ce

ss

or

ie

s

Pa

rts

 / 

Ac

ce

ss

or

ie

s

Summary of Contents for Grandview GV 230

Page 1: ...t en faire la demande Num ro de la pi ce 506223 28 This appliance must be properly installed and operated in order to prevent the possibility of a house fire Please read this entire installation and o...

Page 2: ...quirements 4 Selecting the Proper Venting System 4 Chimney Height Requirements 5 Negative Pressure Warning 5 Clearances to Combustibles 6 7 Floor Protection 6 8 Alcove Floor Protection 8 Specification...

Page 3: ...spectyourchimneyatleastonceamonthduringtheburn Safety and General ing season to check for soot and creosote accumulations Any accumulations over 1 8 thick should be removed by a professional chimney s...

Page 4: ...to the venting system Do not install an offset within the first two feet above the flue outlet on the appliance Inwellinsulatedandweathertighthomes itmaybedifficulttoestablish a good draft up your ch...

Page 5: ...is caused by many common household appliances which exhaust air from the home such as a furnace heat pump air conditioner clothes dryer exhaust fans fireplaces and other fuel burning appliances Also...

Page 6: ...ial chimney systems must be from the same brands as listed for mobile homes but connector pipe may be double wall single wall or single wall with shield as listed This appliance may be vented into a c...

Page 7: ...10 6 3 8 21 11 1 2 8 4 11 16 15 38 5 8 45 33 16 0 90 57 1 2 10 254 162 533 292 200 119 381 981 1143 838 406 0 2286 1461 N A Double Wall Alcove Vertical Vent 13 9 3 8 22 1 2 13 8 N A N A 38 5 8 48 33...

Page 8: ...kM x thickness alternate k value per inch of listed material TM of listed material kL material TL TM inches kM x TL 47 TM inches 35 x 50 47 312 inches 745 x 50 Answer The minimum required thickness o...

Page 9: ...1482 ULC S627 Listing Dimensions Notes Dimensions shown are approximations only 1 4 Diagrams illustrations and photographs are not to scale consult installa tion instructions Product designs materials...

Page 10: ...STAINLESS STEEL LINER Using 6 Diameter Rigid Stainless Steel Liner Figure 6 Typical Installation Figure 7 Connected to a Masonry Chimney Floor Protector Floor Protector Fasten each stove pipe connecti...

Page 11: ...tallations require a spark arrestor at the chimney termination All mobile home installations require an outside air kit see Page 27 for ordering information and the stove must be secured to the floor...

Page 12: ...ll be 12 in 305 mm Chimney section concentric with and spaced 1 in 25 4 mm away from connector by means of sheet steel support plates on both ends of chimney section Opening shall be covered and chimn...

Page 13: ...elow that the stove in located on Leg Installation Figure 11 Pedestal Installation Residential and Mobile Homes Tieing down and grounding are required only in mobile homes Open all cartons if any and...

Page 14: ...FLOOR THE STOVE MUST BE ATTACHED TO THE FLOOR AT NO LESS THAN TWO POINTS Pedestal Locate the two holes on the back of the pedestal Figure 12 Secure the pedestal to the floor using two field provided 1...

Page 15: ...t not be installed more than ten 10 feet 3050 mm above the base of the stove C The fresh air must come from outside the house The air intake must not draw air from the attic from the basement or garag...

Page 16: ...de x 1 5 16 33mm Thick 6 5 7 7 Back Baffle Board Back Baffle Board 7 7 196mm 6 5 165mm Front Baffle Board Front Baffle Board 1 Install firebox bottom brick spacers on both the left and right side of f...

Page 17: ...nd baffle boards are properly installed If plated accessories are used be sure surfacesarecleanpriortofiringthestove See Page 18 FOR YOUR OWN PROTECTION AND INSURANCE PURPOSES HAVE YOUR CHIMNEY AND CO...

Page 18: ...to an imbal ance in the indoor air quality avoid the stove during the curing process Your new Grandview 230 is painted with a high temperature paint that cures during the first few firings We recomme...

Page 19: ...TLY OPEN CAUTION Do Not alter the adjustment range of the draft control for increased firing for any reason Operate only with fuel door and ash drawer closed Maintain all seals in good condition Do no...

Page 20: ...t slightly open during start up 6 For best results use smaller pieces of wood to get the stove tem perature very high before loading larger wood for sustained burns If necessary crack the door to allo...

Page 21: ...gh level of heat transfer efficiency Slowing the rate of flow through the stove or insert enhances heat transfer thus allowing more time for heat to be transferred into your home To do this be sure to...

Page 22: ...r being moved by the blower before the blower is turned on Likewise when the stove cools off the blower is turned off to prevent circulating cool air Depending on the size and intensity of the fire it...

Page 23: ...e chimney and baffle monthly to make sure they are clean DO Burn seasoned dry wood only RAIN WET WOOD DO Open the door frequently during Burn In Period to keep gasket from adhering to the curing paint...

Page 24: ...e back of the stove Using a L shaped 5 32 allen wrench loosen the locking screw in the latch assemblyasshowninFigure31 Withthelockingscrewloosened adjust the top 5 32 allen screw Figure 31 in the fron...

Page 25: ...n above and Cleaning Glass on Page 24 SMOKES WHEN 1 If smoke is entering the room check to make sure your baffle boards are properly installed DOOR IS OPEN and that the baffle blankets are pushed back...

Page 26: ...lack Cast Leg single leg H8382 Leg Hardware Bolt Kit PEDESTAL PARTS H5564 Ash Plug Remover and Rake H8381 Removable Ash Plug BLOWER PARTS Cat No Description H8374 Blower Snap Switch H8375 Blower Blade...

Page 27: ...sh Drawer Kit 6 H8345 ASHDR KIT LEG GV Leg Ash Drawer Kit LOUVERS 7 H8348 LVP GV230 BLK Louvers Black 7 H8349 LVR GV230 BRNKL Louvers Brushed Nickel DOOR TRIM Item Cat No Model Description 8 H8346 DRT...

Page 28: ...LENGTH 3 9 4 6DL36A 6DL36A ADJUSTABLE LENGTH 3 34 2 6DT 6DT TEE TEE CAP INCLUDED 4 6DE45 6DE45 ELBOW 45 DEGREE 4 6DE90 6DE90 ELBOW 90 DEGREE 4 6DMA 6DMA MASONRY ADAPTOR 1 6UP 6UP FLUE EXTENSION 10 6D...

Page 29: ...FC FINISHING SUPPORT W COUPLER 1 Cat No Model Description Pc Container Supports continued 6SM 6SM TEE SUPPORT 1 6SMA 6SMA GALVALUME ADJUSTABLE TEE SUPPORT 2 TO 6 5 SO SO OFFSET SUPPORT WALL SUP PORT 1...

Page 30: ...only parts sup plied from the manufacturer Normally all parts should be ordered through your Lennox distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repa...

Reviews: