C
Page 97
G21V/GSR21V OPERATION SEQUENCE AND JUMPERS SUMMARY WITH VSP1 (HEATING)
MATCH UP
JUMPER
COMMENTS OR SEQUENCE
SingleStage Heating
HB" to W2"
Blower operates on the high
speed heat tap during the heat
ing mode.
TwoStage Heating
No Jumpers
Blower operates on the low
speed heat/cool tap during the
first stage of heating. Modula
tion control S78 will cycle the
unit. Blower operates on the
high speed heat tap during
second stage heating. Modula
tion control S78 may not cycle
the unit.
Harmony Heating
No Jumpers
Blower operates on PWM
signal generated by Har
mony. Harmony overrides
blower speed taps. Blower
speed varies according to
zone demand.
TABLE 21
WIRING CONNECTIONS
W1
W2
R
G
Y1
Y2
DS
HB
W1
W2
R
G
Y1
Y2
DS
C
HB
W1
W2
R
G
Y1
Y2
DS
C
HB
S1
THERMOSTAT
TB1 TERMINAL STRIP
S1
THERMOSTAT
TB1 TERMINAL STRIP
TB1 TERMINAL STRIP
ZONE
CONTROLLER
A1
HARMONY
FOR COOLING JUMPERS
SEE TABLE 22