Page 9
BLOWER DATA (contd.)
(units equipped with an electronically controlled blower motor ICM2)
G21V5−80/100 BLOWER MOTOR PERFORMANCE
(For Static Pressure 0.0" to 0.8" w.g.)
ADJUST
LOW SPEED
HIGH (COOL) SPEED
HEAT SPEED
ADJUST
JUMPER
SETTING
VSP2−1 JUMPER POSITION
VSP2−1 JUMPER POSITION
VSP2−1 JUMPER POSITION
SETTING
1
2
3
4
1
2
3
4
1
2
3
4
+
800
1050
1410
1620
1710
2030
2270*
2270*
1900
2140
2270*
2270*
NORM
720
950
1280
1500
1570
1850
2100
2220
1700
1940
2080
2200
−
620
850
1120
1310
1420
1650
1860
1990
1520
1730
1860
1940
NOTE: ADJUST position on JPB1 (NORM", +", or −") determines the row of CFM available to use.
*2300 CFM @ 0.2" w.g.; 2250 CFM @ 0.5" w.g.; 2200 CFM @ 0.8" w.g.
NOTE All air data is measured external to the unit with the air filter in place.
Blower maintains a constant CFM throughout a range of varying static pressures.
GSR21V3−80 BLOWER MOTOR PERFORMANCE
(For Static Pressure 0.0" to 0.8" w.g.)
ADJUST
LOW SPEED
HIGH (COOL) SPEED
HEAT SPEED
ADJUST
JUMPER
SETTING
VSP2−1 JUMPER POSITION
VSP2−1 JUMPER POSITION
VSP2−1 JUMPER POSITION
SETTING
1
2
3
4
1
2
3
4
1
2
3
4
+
520
670
800
960
1110
1220
1340
1420
1110
1210
1310
1420
NORM
480
600
740
880
1070
1160
1270
1300
1000
1100
1200
1280
−
420
550
650
770
950
1040
1150
1170
900
1000
1100
1160
NOTE: ADJUST position on JPB1 (NORM", +", or −") determines the row of CFM available to use.
NOTE All air data is measured external to the unit with the air filter in place.
Blower maintains a constant CFM throughout a range of varying static pressures.
GSR21V5−80/100 BLOWER MOTOR PERFORMANCE
(For Static Pressure 0.0" to 0.8" w.g.)
ADJUST
LOW SPEED
HIGH (COOL) SPEED
HEAT SPEED
ADJUST
JUMPER
SETTING
VSP2−1 JUMPER POSITION
VSP2−1 JUMPER POSITION
VSP2−1 JUMPER POSITION
SETTING
1
2
3
4
1
2
3
4
1
2
3
4
+
860
1100
1460
1740
1800
2090
2100
*
2100
*
1930
2100
*
2100
*
2100
*
NORM
770
1020
1390
1580
1720
1990
2100
*
2100
*
1800
2000
2100
*
2100
*
−
680
900
1180
1400
1450
1690
1940
2040
1580
1780
1920
2010
NOTE: ADJUST position on JPB1 (NORM", +", or −") determines the row of CFM available to use.
*2200 CFM @ 0.2" w.g.; 2100 CFM @ 0.5" w.g.; 2000 CFM @ 0.8" w.g.
NOTE All air data is measured external to the unit with the air filter in place.
Blower maintains a constant CFM throughout a range of varying static pressures.