26
1195
149
1195
790
416
605
416
848
101
246
Square discharge duct
Inlet
plenum
980
848
31
101
Inlet
plenum
Square discharge duct 848x848
149
1195
1209
416
790
790
416
1195
101
246
101
62
101
1195
416
BMS
(Interface Mod-bus KP06+Bus Adapter)
It is possible to connect several units with a communication system (MOD BUS Protocol).
ALARM RELAY
It is a free voltage contact which indicates a general alarm in the unit.
DYNAMIC SET POINT (Not available for units EAC 0472 to 0812).
It changes cooling and heating set point according ambient temperature (an extra sensor must be installed).
COMPRESSOR NOISE INSULATION JACKET
Each compressor is fitted with a compressor acoustic jacket this provides attenuation of the compressor noise that radiates from
the unit when in operation.
SOFT STARTER
(for 3N~400V units only)
It is an electronic element, which reduces the peak compressor starting current up to 40%.
INLET PLENUM
(models from 0251 to 1303 only)
It is a accessory for adapting the condenser air intake to accept a duct.
SQUARE DISCHARGE DUCT
(FP1 and FP2 unit versions and models from 0251 to 1303 only)
It is formed by 1 or 2 square frames, for adapting discharge air from the unit to a square duct.
WATER PUMP
(included on Hydraulic and Hydronic versions).
TWIN PUMPS KIT
(models from 0251 to 1303 only)
It is formed by two-water pumps mounted in parallel and with same characteristics as a single pump. Only one pump is working,
the other remains on stand by.
When the water pump which is operating cuts out, and the pump turns off, automatically starting the water pump on stand by.
It is possible to select which one of the pumps we want to be working through an external switch supplied with the kit.
With the twin pumps, the available static pressure will decrease 5% from the available static pressure with one water pump only.
TANK ANTI-FREEZE HEATER AND WATER TANK ELECTRICAL HEATER
(available only for Hydronic version): an immersion
heater can be supplied complete with safety thermostat and pressure switch fitted in the buffer tank, or an anti-freeze and
supplementary heater (heat pump units only).
Tank anti-freeze heater:
It starts when water temperature in the buffer tank is lower than +5ºC (Not for units with low water
temperature kit).
Water tank electrical heater:
heat pump units only. The heater works as anti-freeze heater as explained before and as supplementary
heater, when inlet warm water reaches a temperature below a value selected (example: 30ºC) through an independent thermostat
included.
LOW WATER TEMPERATURE
Necessary for water outlet temperatures below +5ºC
There are three different kits, which depend for selecting on the water outlet temperature desired, as the following table shows:
THE POWER INPUT IS:
Application duty on the water outlet temperature
KIT LOW WATER TEMPERATURE 0ºC
KIT LOW WATER TEMPERATURE -5ºC
KIT LOW WATER TEMPERATURE -10ºC
For water temperatures below 5ºC to 0ºC
For water temperatures below 0ºC to -5ºC
For water temperatures below -5ºC to -10ºC
Denomination
1.- GENERAL CHARACTERISTICS
1.10.- OPTIONS
0251 to 0431 MODELS
0472 to 0812 MODELS
1003 to 1303 MODELS
106
324
149
62
416
1495
1170
1140
1140
Inlet
plenum
Square discharge duct 848x848
104
1420
416
1495
600
106
Models
Voltage v
0472/0812
0251/0431
Tank anti-freeze heater
Water tank electrical heater*
0091/0211
kW
1003/1303
3~230V - 3~400V
2,25
2,25
12
9
1N~230V
2,25
6
6
24
3~400V
(*) Heat pump units only
kW