Venting Kits and Available Components

The following is a list of venting kits and components approved for use with the gas fireplace:

Catalog

Number

Description

96K70

12” Compressed Flex Termination (Round)

96K71

18” Compressed Flex Termination (Round)

96K72

24” Compressed Flex Termination (Round)

96K73

36” Compressed Flex Termination (Round)

96K74

48” Compressed Flex Termination (Round)

98K08

12” Compressed Flex Termination (Square)

98K09

18” Compressed Flex Termination (Square)

98K10

24” Compressed Flex Termination (Square)

98K11

36” Compressed Flex Termination (Square)

98K12

48” Compressed Flex Termination (Square)

96K80

Firestop Spacer - Horizontal Vent

96K82

1’ Coaxial Unitized Rigid Pipe

96K83

2’ Coaxial Unitized Rigid Pipe

96K84

3’ Coaxial Unitized Rigid Pipe

96K85

5’ Coaxial Unitized Rigid Pipe

96K86

1’ Coaxial Adjustable Pipe

96K87

Firestop Spacer - Vertical Vent

96K88

90

_

Elbow

96K89

45

_

Elbow

96K90

Flat Roof Flashing

96K91

1/12 - 7/12 Pitched Roof Flashing

97K01

8/12 - 12/12 Pitched Roof Flashing

96K92

Support Plate

96K93

Support Strap

96K94

Attic Insulation Shield

96K95

Horizontal Term. for Rigid Pipe (Round)

96K96

Vertical Term. for Rigid Pipe (Round)

98K13

Horizontal Term. for Rigid Pipe (Square)

12L01

JVEXT4 - 4” Vent Extension

96K13

Circulating Air Fan

96K14

Circ. Air Fan with Temp. Control & Rheostat

96K98

Termination Heat Deflector

96K99

Riser Kit (Flex connections only)

97K00

Wall Termination Heat Guard

10K81

Mill-Pac Black High Temperature Sealant

97K72

30” Grate Kit

97K73

35” Grate Kit

97K74

40” Grate Kit

97K75

45” Grate Kit

96K16

30” 4-Piece Polished Brass Trim Assembly

96K17

35” 4-Piece Polished Brass Trim Assembly

Catalog

Number

Description

96K18

40” 4-Piece Polished Brass Trim Assembly

96K19

45” 4-Piece Polished Brass Trim Assembly

96K20

30” 3-Piece Polished Brass Trim Assembly

96K21

35” 3-Piece Polished Brass Trim Assembly

96K22

40” 3-Piece Polished Brass Trim Assembly

96K23

45” 3-Piece Polished Brass Trim Assembly

96K15

Free-Standing Heat Guard (40/45”Models)

96K30

30” Heat Guard

96K31

35” Heat Guard

96K32

40” Heat Guard

96K33

45” Heat Guard

11K97

Free-Standing Heat Guard (30/35”Models)

96K15

Free-Standing Heat Guard (40/45”Models)

96K34

3/8”Stainless Steel Flex Connector (12”)

96K35

3/8”Stainless Steel Flex Connector (24”)

26N04

Remote Control

98K99

Deluxe Remote Control

60P60

White-Rodgers 1E30W-60 Thermostat (F

_

)

10N64

White-Rodgers 1E30W-60 Thermostat (C

_

)

96K09

Brickaded Interior for 30” Rear Vent Units

96K10

Brickaded Interior for 35” Rear Vent Units

96K11

Brickaded Interior for 40” Rear Vent Units

96K12

Brickaded Interior for 45” Rear Vent Units

96K05

Brickaded Interior for 30” Top Vent Units

96K06

Brickaded Interior for 35” Top Vent Units

96K07

Brickaded Interior for 40” Top Vent Units

96K08

Brickaded Interior for 45” Top Vent Units

96K40

On/Off Switch (Unit-mounted)

96K41

Split Logs - 30”

96K42

Split Logs - 35”

96K43

Split Logs - 40”

96K44

Split Logs - 45”

96K45

30” Polished Brass 2-pc. Bustle w/Side Strips

96K46

35” Polished Brass 2-pc. Bustle w/Side Strips

96K47

40” Polished Brass 2-pc. Bustle w/Side Strips

97K48

45” Polished Brass 2-pc. Bustle w/Side Strips

96K49

30” Polished Brass 6-pc. Louvers

96K50

35” Polished Brass 6-pc. Louvers

96K51

40” Polished Brass 6-pc. Louvers

96K52

45” Polished Brass 6-pc. Louvers

Summary of Contents for DR3025

Page 1: ...on Clearances 5 Framing 6 Installation 6 Venting 12 Gas Piping 21 Unit Start up 21 Adjustments 23 Service 24 Wiring Diagram Millivolt Gas Valves 24 Wiring Diagram Electronic Gas Valves 25 Repair Parts...

Page 2: ...ed firebox lining forced air fan assemblies a wall thermostat for use with vented gas fireplace heater models only and hand held remote ON OFF controls are available as options Refer to table 1 for mo...

Page 3: ...rical components if applicable are protected from water When 120 volt power is installed appliance must be elec trically grounded in accordance with local codes In addi tion in the United States insta...

Page 4: ...his includes restrictions on horizontal and ver tical vent lengths and vent termination locations 2 Center appliance between two wall studs if possible to simplify venting 3 If optional blower is used...

Page 5: ...10 254 MANTEL 8 203 MANTEL 6 152 MANTEL 4 102 MANTEL 4 102 14 356 12 305 10 254 2 51 MANTEL TOP OF APPLIANCE 6 152 NOTE Eyebrow shown as positioned in louvered front model The eyebrow position in the...

Page 6: ...he appliance Joints between the finished wall and the fireplace edges can only be sealed with a 300_F 149_C minimum sealant Non combustible materials can be used to cover the gap between the combustib...

Page 7: ...DT DTH DR DRH 3025 LOG PLACEMENT Log Stamping Part Number Log Number 1 195 2 196 3 197 4 198 Lennox Part Number Lennox Part Number for entire log set 18L76 19L60 19L61 19L62 19L63 4 2 1 3 2 3 4 1 FIG...

Page 8: ...DT DTH DR DRH 3530 LOG PLACEMENT Log Stamping Part Number Log Number 1 199 2 1910 3 1911 4 1912 2 3 4 1 Lennox Part Number Lennox Part Number for entire log set 18L77 19L64 19L65 21L10 21L11 4 2 1 3 F...

Page 9: ...LOG PLACEMENT Log Stamping Part Number Log Number 1 1919 2 1918 3 1920 4 1923 Lennox Part Number Lennox Part Number for entire log set 18L78 19L67 19L66 19L68 19L69 5 6 1921 19L70 1922 19L71 2 3 4 1...

Page 10: ...CEMENT Log Stamping Part Number Log Number 1 1924 2 1925 3 1920 4 1922 Lennox Part Number 19L72 19L73 19L68 19L71 5 6 1923 19L69 1921 19L70 1926 19L74 7 4 2 1 3 6 5 7 2 3 1 5 4 6 7 Lennox Part Number...

Page 11: ...g to figure 37 Electronic Ignition Units All electronic ignition units require 120 volt wiring Install wiring according to fig ure 38 When 120 volt electrical power is applied the ap pliance must be e...

Page 12: ...collars before assembling vent to collar Outer pipe must also be se cured to outer collar using three sheet metal screws See figure 11 Sealant must be applied to all rigid pipe joints and the outer pi...

Page 13: ...ESTRICTOR TOP FLUE OUTLET FIGURE 13 1 Provide a firestop spacer any time vent pipe must pass through a combustible floor ceiling or wall See figure 14 Refer to listing on page 26 for catalog num bers...

Page 14: ...2 ft min 6 ft max 3 ft min 9 ft max 4 ft min 12 ft max 5 ft min 15 ft max 17 ft max 6 ft min H V1 V2 V1 V2 40 ft Maximum H 17 ft Maximum Firestop Spacer must be used any time vent pipe passes through...

Page 15: ...t min 4 ft max 3 ft min 6 ft max 4 ft min 8 ft max 40 ft max 8 ft max H2 H1 V Firestop Spacer must be used any time vent pipe passes through combustible floor or ceiling or wall FIGURE 20 VERTICAL VEN...

Page 16: ...use only with Lennox approved concentric vent pipe either rigid or flexible vent pipe may be used when horizontally venting the fireplace through a side wall DT DTH Applications See figures 23 24 or...

Page 17: ...max 15 ft max V1 H1 H2 6 ft min 17 ft max 20 ft max 17 ft max Firestop Spacer must be used any time vent pipe passes through combustible floor or ceiling or wall RIGID VENT PIPE SHOWN FLEXIBLE VENT P...

Page 18: ...top Spacer must be used any time vent pipe passes through combustible floor or ceiling or wall RIGID VENT PIPE SHOWN FLEXIBLE VENT PIPE MAY ALSO BE USED NOTE THE LONGEST LENGTH OF FLEX AVAILABLE IS 48...

Page 19: ...MINATION AT TOP 3 in 76mm 1 in 25mm FIRESTOP SPACER AT INSIDE WALL SURFACE FACEPLATE INTEGRAL TO VENT TERMINATION VENT TERMINATION The termination faceplate shall not be recessed into a wall or siding...

Page 20: ...vice regulator vent outlet 3 ft 915mm in the United States and 6 ft 1 8m in Canada minimum J Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance...

Page 21: ...32 LEAK CHECK After gas piping is completed carefully check all piping connections factory and field for gas leaks Use a leak detecting solution or other preferred means CAUTION Some soaps used for l...

Page 22: ...ob counterclock wise to ON 9 Restore electrical power to appliance if applicable 10 Turn ON the burner switch if applicable or set the thermostat to the desired setting if applicable 11 Close the bott...

Page 23: ...roved for elevations of 0 4500 feet 0 1372 meters When installing this unit at an elevation above 4500 feet 1372 meters consult the local authorities having jurisdiction ELECTRICAL NOTE These checks a...

Page 24: ...e and outside glass surfaces using a mild deter gent water solution and a soft cloth DO NOT use abrasive cleansers which might scratch the high temperature glass surface DO NOT clean glass when surfac...

Page 25: ...Unit mounted ON OFF switch is available as a factory installed option or can be ordered separately and field installed Wall mounted ON OFF switch is field provided Thermostat is available as a factor...

Page 26: ...it 97K75 45 Grate Kit 96K16 30 4 Piece Polished Brass Trim Assembly 96K17 35 4 Piece Polished Brass Trim Assembly Catalog Number Description 96K18 40 4 Piece Polished Brass Trim Assembly 96K19 45 4 Pi...