Page 4
SLP98UHV Gas Furnace
The SLP98UHV category IV gas furnace is equipped with
a variable−capacity, variable−speed integrated control.
This control ensures compatibility with the Lennox icom-
fort Touch
t
thermostat, the Harmony III
t
zone control
system, or a thermostat which provides humidity control.
Each SLP98UHV is shipped ready for installation in the
upflow, horizontal left air discharge or horizontal right air
discharge position.
The furnace is equipped for installation in natural gas ap-
plications only. A changeover kit may be ordered for LP
applications.
The SLP98UHV must be installed only as a Direct Vent
gas furnace.
NOTE
− In Direct Vent installations, combustion air is taken
from outdoors and flue gases are discharged outdoors. See
figure 2 for applications including roof termination.
FIGURE 2
DIRECT VENT INSTALLATION
EXHAUST OUTLET
COMBUSTION
AIR INTAKE
OUTSIDE OF
HOUSE
Shipping and Packing List
Package 1 of 1 contains
1 − Assembled SLP98UHV unit
1 − Bag assembly containing the following:
1 − Snap bushing
1 − Snap plug
1 − Wire tie
1 − Condensate trap
1 − Condensate trap cap
1 − Condensate trap cap clamp
1 − 3/4" Threaded street elbow
Check equipment for shipping damage. If you find any
damage, immediately contact the last carrier.
The following items may also be ordered separately:
1 − Thermostat
1 − Natural to LP gas conversion kit
1 − High altitude kit
1 − Horizontal suspension kit
DANGER
Danger of explosion.
There are circumstances in which odorant used with
LP/propane gas can lose its scent. In case of a leak,
LP/propane gas will settle close to the floor and may
be difficult to smell. An LP/propane leak detector
should be installed in all LP applications.
Safety Information
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, person-
al injury or loss of life. Installation and service must
be performed by a licensed professional installer (or
equivalent), service agency or the gas supplier.
CAUTION
As with any mechanical equipment, personal injury
can result from contact with sharp sheet metal
edges. Be careful when you handle this equipment.
Use only the type of gas approved for use with this furnace.
Refer to unit nameplate.
Building Codes
In the USA, installation of gas furnaces must conform with lo-
cal building codes. In the absence of local codes, units must
be installed according to the current National Fuel Gas Code
(ANSI-Z223.1/NFPA 54). The National Fuel Gas Code is
available from the following address:
American National Standards Institute, Inc.
11 West 42nd Street
New York, NY 10036
Installed Locations
In Canada, installation must conform with current National
Standard of Canada CSA-B149 Natural Gas and Propane
Installation Codes, local plumbing or waste water codes
and other applicable local codes.
This furnace is designed for installation clearances to com-
bustible material as listed on the unit nameplate and in the
tables in figures 10 and 11. Accessibility and service clear-
ances must take precedence over fire protection clearances.
NOTE
− For installation on combustible floors, the furnace
shall not be installed directly on carpeting, tile, or other
combustible material other than wood flooring.
For installation in a residential garage, the furnace must
be installed so that the burner(s) and the ignition source
are located no less than 18 inches (457 mm) above the
floor. The furnace must be located or protected to avoid
physical damage by vehicles. When a furnace is installed