background image

NATURAL AND PROPANE GAS TWO STAGE

HIGH EFFICIENCY (CONDENSING) WARM AIR FURNACE

MODELS STARTING WITH G95V

 P/N 240006752, Rev. A [04/07]

An ISO 9001-2000 Certifi ed Company

ECR INTERNATIONAL LTD.

P.O. Box 900, 6800 Base Line
Wallaceburg, ON N8A 5E5
Canada

www.ecrltd.com

USERʼS INFORMA

TION MANU

AL

!  

!  

!  

!  

WARNING

IF THE INFORMATION IN THESE INSTRUC-
TIONS IS NOT FOLLOWED EXACTLY, A FIRE 
OR EXPLOSION MAY RESULT, CAUSING 
PROPERTY DAMAGE, PERSONAL INJURY 
OR LOSS OF LIFE.

WARNING

FOR YOUR SAFETY

DO NOT STORE OR USE GASOLINE OR OTH-
ER FLAMMABLE VAPORS AND LIQUIDS, OR 
OTHER COMBUSTIBLE MATERIALS IN THE VI-
CINITY OF THIS OR ANY OTHER APPLIANCE.

WHAT TO DO IF YOU SMELL GAS

DO NOT TRY TO LIGHT ANY APPLIANCE.
DO NOT TOUCH ANY ELECTRICAL 
SWITCH; DO NOT USE ANY PHONE IN 
YOUR BUILDING.
IMMEDIATELY CALL YOUR GAS SUP-
PLIER FROM A NEIGHBOR’S PHONE, 
OR A CELLULAR PHONE FROM A LO-
CATION WELL AWAY FROM THE BUILD-
ING. FOLLOW THE GAS SUPPLIER’S 
INSTRUCTIONS.
IF YOU CANNOT REACH YOUR GAS SUP-
PLIER, CALL THE FIRE DEPARTMENT.
DO NOT RE-ENTER THE BUILDING UN-
TIL AUTHORIZED TO DO SO BY THE GAS 
SUPPLIER OR THE FIRE DEPARTMENT.

IMPROPER INSTALLATION, ADJUSTMENT, 
ALTERATION, SERVICE OR MAINTENANCE 
CAN CAUSE INJURY, PROPERTY DAMAGE 
OR LOSS OF LIFE. REFER TO THIS MANUAL.

INSTALLATION AND SERVICE MUST BE 
PERFORMED BY A QUALIFIED INSTALLER, 
SERVICE AGENCY OR THE GAS SUPPLIER.


IMPORTANT:

 Read these instruc-

tions thoroughly before attempting to 
operate this furnace.

DO NOT DESTROY THIS MANUAL

Please read carefully and keep in a 
safe place for future reference by a 
service technician.

!  

!  

SHOULD OVERHEATING OCCUR 
OR THE GAS BURNERS FAIL TO 
SHUT OFF, CLOSE THE MANUAL 
GAS VALVE FOR THE FURNACE 
BEFORE SHUTTING OFF THE 
ELECTRICAL POWER TO THE 
FURNACE. FAILURE TO DO SO 
CAN CAUSE AN EXPLOSION OR 
FIRE RESULTING IN PROPERTY 
DAMAGE, PERSONAL INJURY OR 
LOSS OF LIFE.

BEFORE RESTARTING THE FUR-
NACE, CHECK ALL PLASTIC 
VENTS AND WIRES FOR DAM-
AGE.

WARNING

Summary of Contents for G95V UltraComfort 95V

Page 1: ...A LO CATION WELLAWAY FROM THE BUILD ING FOLLOW THE GAS SUPPLIER S INSTRUCTIONS IFYOUCANNOTREACHYOURGASSUP PLIER CALL THE FIRE DEPARTMENT DO NOT RE ENTER THE BUILDING UN TILAUTHORIZED TO DO SO BYTHE GA...

Page 2: ...NING Indicates a potentially hazardous situation which if not avoided COULD result in death or serious injury CAUTION Indicates a potential hazardous situation which if not avoided MAY result in minor...

Page 3: ...OR DEATH YOUR GAS SUPPLIER SHOULD PERIODI CALLY INSPECT AND CLEAN THE AIR VENT SCREEN TO PREVENT ANY OBSTRUCTION KEEP PROTECTIVE REGULATOR COVER IN PLACE AS EXPOSURE TO THE ELEMENTS CAN CAUSE ICE BUI...

Page 4: ...rature and shorten the life of furnace components 11 Do not cover return air grills and supply air reg isters with drapes curtains throw rugs etc 12 Avoid shutting off supply air registers in the inte...

Page 5: ...e lter is re installed with the air ow direction identical to its previous use Reversing the lter will cause dust trapped within the lter to break free and recirculate within the duct system LUBRICATI...

Page 6: ...URNACE APPEARANCE The furnace exterior nish is a durable automo tive like coating It may be washed with mild soap if necessary Galvanized metal surfaces require no maintenance CLEANING It is advisable...

Page 7: ...home comfort Each pound of condensation formed releases approximately 970 BTUs Your fur nace may condense up to gallon 5 pounds of water per hour if running continuously This condensation must be pro...

Page 8: ...two stage thermostat the control de energizes the high gas output and immedi ately changes inducer speed from high to low With the thermostat heating contacts open single stage thermostat the ames ex...

Reviews: