10
User Settings Menu
Table 3. User Settings (General)
Setting Selection
Function
Description
fan
See “Fan Operation” on page 6.
heat / cool (either heat
pump, gas or electric
heating is selected)
normal
Heats home to desired tempera ture setting. Options are on or off.
comfort
If system is two-stage heating or cooling, then 2nd stage is locked in
until demand is satisfied.
emergency
heat
Bypasses the first stage of heating (any stage[s] of heat pump heating)
and goes directly to the heat stage used for maximum heating to more
quickly warm a very cold house.
set point
range
Heating limit with a default of 0°F. Range is 45°F to 90°F
Cooling limit with a default of 45°F. Range is 45°F to 99°F
cool only (option only
appears if no heating
equipment is avail able or
configured)
set point
range
Cooling limit with a default of 45°F. Range is 45°F to 99°F
humidity - Allows selection
of dehumidification. Option
only available if enabled in
installer settings.
dehumidify
Options are ON and OFF. Allows dehumidify adjustment setting
between 45% to 60%. Default is 50%.