background image

4

•  From the override setting screen, the 

options are 1 hour, 2 hour or next scheduled 

period. Make selection and then touch set.

• 

For  the  1  or  2  hour  setting  the  home 

screen will indicate schedule hold until time 

indicated (i.e., 11:57 pm). To exit schedule 

hold, touch 

X

• 

When until next period is selected, the set 

point  will  be  kept  until  the  next  program 

schedule  period.  To  exit  until  next  period, 

touch 

X

.

K. 

System Status Icons

 - Equipment operation 

information appears along the left side of the 

home screen. The displayed icons will indicate 

cooling or heating demand, cooling compressor 

delay, or cooling demand.

Table 1. System Status Icons

Icon

Description

NOTE: 

Touching the icon will display a 

text description.

Humidifying icon is displayed when 

humidifying is occurring. Touching on 

the icon will display humidifying next to 

the icon.
Dehumidifying icon is displayed when 

dehumidifying is occurring. Touching 

the icon will display dehumidifying next 

to the icon.

Red flames indicates the system is 

heating.

Table 1. System Status Icons

Icon

Description

NOTE: 

Touching the icon will display a 

text description.

Blue flames indicates the system is 

cooling.

Snow flake indicates the next mode 

of operation will be cooling. Waiting 

indicates there is a compressor delay 

which is by default five minutes.
Red flame indicates the next mode 

of operation will be heating. Waiting 

indicates there is a compressor delay 

(heat pump heating) which has a default 

of five minutes and is not adjustable.

Indicates the system is running in 

emergency heat mode.
All heat pumps operating in northern 

climates below 35°F (1.6°C) normally 

need a supplemental heating source. 

Usually it is in the form of electric 

heating provided by the indoor unit. 

Other sources could be gas, oil, or 

hot-water back-up systems as well. The 

supplemental heat is also referred to 

as “second-stage” or “back-up” heating, 

with “first-stage” being the heat pump 

only. Emergency heat is when you use 

your supplemental heat (2nd stage) by 

itself, without the use of your heat pump 

(1st stage heat). Not available for non-

heat pump systems.

Summary of Contents for ComfortSense 7500 Series

Page 1: ...507505 02 6 2018 Supersedes 5 2017 ComfortSense 7500 Commercial Thermostat User Guide...

Page 2: ...free memory storage feature menu driven touch screen display dehumidification measurement and control Humiditrol EDA capability Home Screen Temperature Indicator 2 31 am thurs heat to cool to 80 insid...

Page 3: ...emperature dial position indicator will take you to the temperature setting detail screen The temperature dial will change from white to red when heating is active F This allows you to set the cool to...

Page 4: ...ifying next to the icon Red flames indicates the system is heating Table 1 System Status Icons Icon Description NOTE Touching the icon will display a text description Blue flames indicates the system...

Page 5: ...nd 6 F per hour for first stage compressor based cooling When smooth set back recovery is disabled the control will start recovery at the programmed time set in the schedule L Holiday Mode Selecting t...

Page 6: ...ng scheduling for the current period the ther mostat will indicate the current fan mode in the in formation display FAN ON or FAN CIRC In the CIRCULATE mode the fan will follow the setting configured...

Page 7: ...or set a future reminder Any active history for notifications critical errors or reminders will be listed under settings notification If critical errors occur they will also be displayed under notifi...

Page 8: ...Selection on page 5 to run a specific schedule From the HOME screen touch the MENU and touch edit schedules option The edit schedules screen will allow section of up too three separate schedules On th...

Page 9: ...end all 7 days All days wake rename time cool to heat to fan occupancy time select time or delete period If period deleted A maximum of four time periods can be used If any time periods are deleted an...

Page 10: ...age s of heat pump heating and goes directly to the heat stage used for maximum heating to more quickly warm a very cold house set point range Heating limit with a default of 0 F Range is 45 F to 90 F...

Page 11: ...ngs for screen lock date time and language about Displays information concerning thermostat model number serial number hardware and software revisions screen lock Setting options are unlocked partiall...

Page 12: ...displayed on the home screen Outdoor temperature display or discharged air display what is displayed here depends on sensor used and configured by installer Options are off or sensor screen saver Opti...

Reviews: