icomfort
Wi-Fi
7−Day Programmable Communicating Thermostat
Page 41
Table 3. Adjustable Parameters Table (Installer)
Parameter Name
Installer entry
Note
Dependency
Incr.
Max.
Min.
Default
Cooling Airflow Settings
High Cooling Airflow (CFM @ 100%
cool)
OU tons
400CFM
Min
CFM
Max
CFM
25
Outdoor Unit
present
1/2 HP blower
Min
CFM
Max
CFM
25
1 HP blower
Low Cooling Airflow (CFM @ lowest
cool stage)
(See
Note 1
at end of
table)
Min
CFM
Max
CFM
25
2+ stage Outdoor
Unit present
1/2 HP blower
Min
CFM
Max
CFM
25
1 HP blower
Airflow Profile − Cooling
DIP SW
0
3
1
Outdoor Unit
present
0 A:ON:50%/30s,82% /
7.5min OFF:50%/30s
1 B:ON:82% / 7.5min; OFF:
No delays
2 C:ON: No delays; OFF:
45sec delay
3 D:No delays)
Heat Pump Airflow Settings
High Heat Pump Airflow (CFM @
100%)
OU tons
400CFM
Min
CFM
Max
CFM
25
Heat Pump present
1/2 HP blower
Min
CFM
Max
CFM
25
1 HP blower
Low Heat Pump Airflow (CFM @
lowest stage)
(See
Note 2
at end of
table)
Min
CFM
Max
CFM
25
2+ stage Heat Pump
present
1/2 HP blower
Min
CFM
Max
CFM
25
1 HP blower
table continued on next page