icomfort
Wi-Fi
7−Day Programmable Communicating Thermostat
Page 17
Adjust a setting... Configure Dehumidification
(no dehumidifying device installed)
(skip if default Basic" dehumidification mode is desired)
edit
about
To adjust a setting, highlight it,
then press Edit
reinstall
next
back
edit
reset
Dehumidification Control Mode
current value:
back
Display Only
Display Only
Basic
Precision
Select one
Dehumidification Control Mode
cancel
save
3b
3a
edit
reset
back
Dehumidification Control Mode
current value:
Precision
9:39 am Aug 15, 2012
please view and save all
red settings
Pre−adjustment REQUIREMENTS:
1st
,
NO
physical dehumidification device has been
installed
.
2nd
, configure the thermostat for dehumidification as follows:
1.
In the system devices" list, use the arrows (
1a
) to highlight
System
.
Press
edit
(
1b
).
2.
In the System" list, use the arrows (
2a
) to highlight
Dehumidification
Control Mode.
The current value defaults to Display Only. Press
edit
(
2b
).
3.
Touch one of the radio buttons (
3a
) to select the mode of dehumidification
control; press
save
(
3b
).
4.
Use arrows (
4a
) to highlight any red colored text in the list (e.g. select Min
Dehumidification Setpoint). Press
edit
(
4b
).
5.
Use arrows (
5a
) to make changes; press
save
(
5b
). Change other red
settings (e.g. Auto Changeover − Humidif. Deadband) using a similar
process.
6.
Press the
back
button to return to Adjust a setting..." screen.
NOTE − If the defaults are correct, you do not have to make any changes, but you
must press
save
(
5b
). When all red text is gone, the
back
button will appear; press it
to return to the Add or Remove Non−communicating equipment?" screen.
1a
1b
2a
2b
4a
4b
System
Staged Delay Timers
Balance Point Control
Dehumidification Control Mode
Humidification Control Mode
Auto Changeover − Humidif. Deadband
Max Humidification Setpoint
Min Dehumidification Setpoint
OK/Humid Boundary
Outdoor Temperature Reading
System Devices
System
Furnace
Thermostat
2 Stage AC Unit
Power (120VAC) Humidifier
System
2nd Stage Differential
Staged Delay Timers
2nd Stage Delay
Dehumidification Control Mode
Humidification Control Mode
OK/Humid Boundary
Outdoor Temperature Reading
System
Min Dehumidification Setpoint
Range is 40 to 60
Default is 45, inc:1
cancel
save
set−to
45
5a
5b
6