Page 4
CBX32MV
CBX32MV‐018/024
BLOWER MOTOR WATTS AT NORM SETTING
(Adjust Jumper at NORM Setting)
Jumper Speed Positions
Motor Watts @ Various External Static Pressures - in. wg. (Pa)
0 (0)
0.1 (25)
0.2 (50)
0.3 (75)
0.4 (100)
0.5 (125)
0.6 (150)
0.7 (175)
0.8 (200)
HEAT
Speed
Tap 1
77
96
106
123
130
150
165
178
201
Tap 2
118
136
154
177
189
212
224
247
265
Tap 3
183
198
224
248
264
284
307
321
343
Tap 4
264
284
300
326
343
367
385
406
390
COOL
Speed
Tap 1
30
41
55
62
76
86
94
106
114
Tap 2
71
83
101
113
125
138
156
166
185
Tap 3
137
158
176
199
219
238
254
273
296
Tap 4
211
225
249
272
295
318
331
342
367
CBX32MV‐018/024
BLOWER MOTOR WATTS AT - (Minus) SETTING
(Adjust Jumper at - Setting)
Jumper Speed Positions
Motor Watts @ Various External Static Pressures - in. wg. (Pa)
0 (0)
0.1 (25)
0.2 (50)
0.3 (75)
0.4 (100)
0.5 (125)
0.6 (150)
0.7 (175)
0.8 (200)
HEAT
Speed
Tap 1
59
73
89
106
113
130
142
156
173
Tap 2
95
106
118
136
152
171
183
200
215
Tap 3
132
148
171
186
211
225
248
266
284
Tap 4
195
217
242
259
283
302
314
336
349
COOL
Speed
Tap 1
27
35
47
59
71
77
88
92
106
Tap 2
57
65
83
94
110
119
134
148
166
Tap 3
110
124
141
157
176
188
213
231
242
Tap 4
148
170
195
207
230
248
272
282
306
CBX32MV024/030 BLOWER PERFORMANCE
0 through 0.80 in. w.g. External Static Pressure Range
“AJUST”
Jumper Setting
Jumper Speed Positions
“HEAT” Speed
“COOL” Speed
1
cfm
2
cfm
3
cfm
4
cfm
1
cfm
2
cfm
3
cfm
4
cfm
+
800
935
1070
1210
660
880
1100
1320
NORM
725
850
975
1100
600
800
1000
1200
-
655
765
880
990
540
720
900
1080
NOTES:
The effect of static pressure, filter and electric heater resistance is included in the air volumes listed.
First stage cooling air volume is 70% of COOL speed settings. Continuous fan speed is approximately 28%, 38%, 70% and 100% (Jumper
selectable) of the same secondstage COOL speed selected, minimum 250 cfm.
Lennox Harmony III™ Zone Control applications - minimum blower speed of 250 cfm.
CBX32MV‐024/030
BLOWER MOTOR WATTS AT + (Plus) SETTING
(Adjust Jumper at + Setting)
Jumper Speed Positions
Motor Watts @ Various External Static Pressures - in. wg. (Pa)
0 (0)
0.1 (25)
0.2 (50)
0.3 (75)
0.4 (100)
0.5 (125)
0.6 (150)
0.7 (175)
0.8 (200)
HEAT
Speed
Tap 1
65
90
120
145
185
210
240
250
275
Tap 2
95
125
150
185
230
265
310
345
365
Tap 3
140
190
225
250
290
320
350
405
450
Tap 4
215
250
285
315
350
390
440
480
505
COOL Speed
Tap 1
45
60
90
120
140
155
165
185
200
Tap 2
80
110
135
165
205
250
285
315
335
Tap 3
150
195
225
260
295
320
370
425
465
Tap 4
265
315
350
400
440
485
525
555
605