# 48392M005

Page 9

Figure 9

Wiring Diagram

P/N 48396-001

208/230V

-1-60

G

W1

C

R

BLK

RED

YEL

RED

CONT

A

C

T

O

R

THERMOST

A

T

L1

T1

T2

L2

C

H

F

CONDENSER

F

AN MO

T

O

R

COMPRESSOR

CONT

A

C

T

O

R

COMPRESSOR

CONT

A

C

T

O

R

DU

AL

CAP

A

CIT

OR

COMPRESSOR

TRANSFORMER

C

S

R

WHT

L2

L1

BLK

BRN

PUR

RED

RED

BLK

208V

240V

24V

INDOOR

BLO

WER

M

OTO

R

S1

K1

T1

B3

B4

K1-2

C12

B1

K1-1

BLU

YEL

C4

CAP

A

CIT

OR

H

M

L

C

SEE CHAR

T

FOR

WIRING

L

M

OTO

R

SPEED

T

APS

NO

NC

C

BLO

WER

CONTR

OL

A15

BLK

C

G

XFMR-R

R

XFMR-C

FUSE

Y

A15

BLO

WER

GRN

RED

BLU

BLU

YEL

BLU

W1 &

W2 CAN BE USED

T

O

 ST

A

G

E

ELECTRIC HEA

T A

CCESSOR

Y ON 15 & 20KW MODELS

.

5, 7.5

& 10KW HEA

TER A

CCESSORIES

FUNCTION OFF

W1 ONL

Y

.

BLK

BLK

WHT

P-1

P-2

P-4

P-6

P-5

BLU

YEL

YEL

HIGH PRESSURE

SWITCH

(IF USED)

S4

GRN

RED

YEL

P-3

BLU

C

H
M

Unit

F

a

c

tor

y

S

hipped

S

e

tti

n

g

s

C

o

oling

Input

(B

L

K

)

24

LO

W

30

MED

36

HIGH

42

LO

W

48

MED

60

HIGH

BLOWER SPEED CHAR

T

CONTR

OL

NO

TE:

IF ANY OF

THE ORIGINAL

WIRE IS REPLA

CED

,

THE SAME SIZE AND

TYPE

WIRE MUST BE USED

.

USE COPPER CONDUCT

OR ONL

Y

, MIN 75°C

WIRE.

LINE

V

O

LT

A

GE FIELD INST

ALLED

.

W

ARNING-

ELECTRIC SHOCK HAZARD

.

UNIT

MUST BE GR

OUNDED

IN A

CCORD

ANCE

WITH NA

TIONAL AND LOCAL CODES

.

Summary of Contents for 2SA13 Series

Page 1: ...lation of this appliance must conform to the requirements of the National Fire Protection Association the National Electrical Code ANSI NFPA No 70 latest edition in the United States the Canadian Elec...

Page 2: ...THE UNIT as claim may be denied Check the unit rating plate to confirm specifications are as ordered Limitations The unit should be installed in accordance with all national and local safety codes Lim...

Page 3: ...roper operation and service Refer to Table 1 for the minimum clearances to combustibles as well as minimum clearances necessary for servicing and proper unit operation In the U S units may be installe...

Page 4: ...0 6 7 6 6 When connecting electrical power and control wiring to the unit waterproof type connectors must be used so that water or moisture cannot be drawn into the unit during normal operation CAUTIO...

Page 5: ...0 90 C MIN WIRE POWER WIRING 24V CONTROL WIRING NEC CLASS 2 TYPICAL WIRING CONNECTION 1 PHASE GROUND SCREW THERMOSTAT OUTDOOR UNIT THERMOSTAT OUTDOOR UNIT GROUND SCREW POWER WIRING 200 230 3 60 460 57...

Page 6: ...common venting system are not in operation 1 Seal any unused openings in the common venting system 2 Visually inspect the venting system for proper size and horizontal pitch and determine there is no...

Page 7: ...ng air blower is controlled by a timing circuit in the blower control Timings are not adjustable There is no blower on delay after a call for heating or cooling Blower off delay is 90 seconds after th...

Page 8: ...nd outdoor fan and vent motors are permanently lubricated and require no maintenance Outdoor Coil Dirt and debris should not be allowed to accumulate on the outdoor coil surface or other parts in the...

Page 9: ...R R R XFMR C FUSE Y A15 BLOWER GRN RED BLU BLU YEL BLU W1 W2 CAN BE USED TO STAGE ELECTRIC HEAT ACCESSORY ON 15 20KW MODELS 5 7 5 10KW HEATER ACCESSORIES FUNCTION OFF W1 ONLY BLK BLK WHT P 1 P 2 P 4 P...

Page 10: ...and excludes all other warranties express or implied The warrantor does not authorize any person to provide any other warranty or to assume for it any further obligation in connection with the warran...

Reviews: